Visual abstractsVisuals
ResearchEuropean Journal of Vascular and Endovascular Surgery · Mar 14, 2026

National Diagnostic Reference Levels for Endovascular Aneurysm Repair in Sweden

Markusdottir E, Lindén A, Cicek C, Starck J, Smidfelt K, Jonsson M, et al
Cardiothoracic & Vascular SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Objective The 2023 European Society for Vascular Surgery (ESVS) guidelines on radiation safety recommended establishment of national diagnostic reference levels (DRLs) for endovascular procedures, which indicate an expected radiation dose for any given procedure for the average sized patient. The aim of this study was to propose a national DRL for Sweden for standard endovascular aortic repair (EVAR). Methods This was a national registry based study where all EVARs performed in Sweden over a two year period (2021 - 2022) were identified in the Swedish vascular registry, Swedvasc. Patient demographics were extracted from Swedvasc and radiation related parameters were collected at centre level. Multivariable analyses were performed to assess which factors affected fluoroscopy time, total dose area product (DAP), and cumulative air kerma (CAK). The national DRL was defined as the third quartile of all centre specific median values for DAP total. Results Nine hundred and thirty-three procedures at 23 centres were included; 831 (89.1%) intact abdominal aortic aneurysms (AAAs) and 102 (10.9%) ruptured AAAs. The median (interquartile range [IQR]) DAP for EVAR at centre level varied from 28.3 Gy·cm2 (IQR 14.1, 76.1) to 212.7 Gy·cm2 (IQR 196.8, 275.0). Overall, the third quartile of the DAP radiation dose for EVAR in Sweden was 152.6 Gy·cm2. The DAP was a median 81.1  Gy·cm2 and 116.5 Gy·cm2 for intact and ruptured EVARs, respectively (p < .001). The DRL was 147.7 Gy·cm2 and 213.8 Gy·cm2 for intact and ruptured EVARs, respectively. In a multivariable linear regression analysis, rupture, iliac branched repair, access complication, obesity, low centre volume and larger aneurysm were predictors for higher DAP during EVAR. Conclusion The current report proposes a DRL for DAP of 152.6 Gy·cm2 for EVAR procedures in Sweden, with specific benchmark DAP values proposed for subgroups of patients. There is a considerable difference in radiation dose between different centres, suggesting a potential for implementation of improved radiation routines in some centres based on benchmarking.

Topics

Aged; Aged, 80 and over; Female; Humans; Aortic Aneurysm, Abdominal; Aortic Rupture; Diagnostic Reference Levels; Endovascular Aneurysm Repair; Fluoroscopy; Radiation Dosage; Radiation Exposure; Registries

DOI: 10.1016/j.ejvs.2026.03.009 · PubMed: 41839415

Cite this article

Markusdottir E, Lindén A, Cicek C, Starck J, Smidfelt K, Jonsson M. National Diagnostic Reference Levels for Endovascular Aneurysm Repair in Sweden. Eur J Vasc Endovasc Surg. 2026. doi:10.1016/j.ejvs.2026.03.009

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur J Vasc Endovasc Surg · Dec 1, 2025 · Research · Cardiothoracic & Vascular Surgery

Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland

Ann Surg · Aug 14, 2026 · Research · Surgery

Sex- and Age-specific Outcomes After Ruptured Abdominal Aortic Aneurysm Repair: A Nationwide Cohort Study

Eur Radiol · Mar 25, 2026 · Review · Radiology & Imaging

Diagnostic reference levels in interventional neuroradiology: a scoping review

J Vasc Surg · Apr 10, 2026 · Research · Cardiothoracic & Vascular Surgery

Analysis of complex endovascular aneurysm repair in patients with median arcuate ligament compression

Eur J Vasc Endovasc Surg · Nov 29, 2025 · Research · Cardiothoracic & Vascular Surgery

Sex Specific Analysis of Outcomes after Fenestrated and Branched Endovascular Aortic Repair: A Population Based Swedvasc Study