Visual abstractsVisuals
ResearchJournal of Plastic, Reconstructive & Aesthetic Surgery · Nov 5, 2025

No drains, no problem: A description of tissue expander breast reconstruction omitting traditional closed suction drain use

Nguyen A, Harfouche C, Reese M, Otterburn DM, Ray EC, Reid CM
Plastic & Reconstructive SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Drainless tissue expansion has been reported possible, but lacking is a description of the associated demands and implementation. This study describes expectations regarding follow-up frequency, aspiration volumes, and how experiences differ based on reconstruction timing. Methods A retrospective review was performed of patients who underwent prepectoral dual-port tissue expander (TE) placement from February 2023 to December 2024. Medical history, intraoperative details, complications, and periprosthetic aspiration volumes were collected. Results Sixty-six patients making up 94 breasts were included. Average days to point of no aspiration was 21.7 (SD 9.2 days), with an average of 5.5 aspirations (SD 1.9 aspirations). After the first 2 aspirations, percentage of breasts requiring aspirations dropped; 85.1% of breasts required at least 4 aspirations, 44.7% required at least 6%, and 7.4% required at least 8. Less than 50% of breasts required aspirations after 20 days, and less than 20% required aspirations after 30 days. Average drainage per breast during the first three aspirations was 141.4, 133.0, and 123.6 mLs, respectively, and tapered with subsequent aspirations. Compared to early interval-staged reconstruction, immediate reconstruction had greater total drainage (350.7 mLs vs 816.2 mLs, p<0.001) and average drainage per aspiration (80.7 vs 128.4 mLs, p<0.001). Conclusion Drainless breast reconstruction is possible with an equivalent safety profile to the standard approach utilizing drains. This study provides a better understanding of the expected frequency of aspiration sessions and volumes removed during visits. Further, the results provide support for its integration in TE reconstruction with a low rate of infection.

Topics

Humans; Female; Retrospective Studies; Tissue Expansion Devices; Suction; Middle Aged; Tissue Expansion; Mammaplasty; Adult; Drainage; Breast Neoplasms; Aged

DOI: 10.1016/j.bjps.2025.11.001 · PubMed: 41273949

Cite this article

Nguyen A, Harfouche C, Reese M, Otterburn DM, Ray EC, Reid CM. No drains, no problem: A description of tissue expander breast reconstruction omitting traditional closed suction drain use. J Plast Reconstr Aesthet Surg. 2025. doi:10.1016/j.bjps.2025.11.001

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Aesthet Surg J · Jan 24, 2026 · Research · Plastic & Reconstructive Surgery

Short-term Outcomes of Polydioxanone Synthetic Mesh in 2-stage Breast Reconstruction: A Single-Center Comparative Study

Plast Reconstr Surg · Nov 17, 2025 · Research · Plastic & Reconstructive Surgery

Optimal Timing of Expander-to-Implant Exchange after Postmastectomy Radiation Therapy: 90-Day Complications and Patient-Reported Outcomes

J Plast Reconstr Aesthet Surg · Jun 3, 2026 · Randomized trial · Plastic & Reconstructive Surgery

External vacuum expansion showed no significant benefit for breast reconstruction using fat transfer

J Plast Reconstr Aesthet Surg · Nov 13, 2025 · Meta-analysis · Plastic & Reconstructive Surgery

Beam me later: Prepectoral vs subpectoral breast reconstruction before postmastectomy radiotherapy - A systematic review and meta-analysis

J Plast Reconstr Aesthet Surg · Jan 22, 2026 · Meta-analysis · Plastic & Reconstructive Surgery

Predictors of postoperative complications following staged nipple-sparing mastectomy: A systematic review & meta-analysis