ReviewIntensive Care Medicine · Apr 27, 2026

Non-invasive intracranial pressure estimation in the intensive care unit: narrative review of methods and clinical applications

Picetti E, Biasucci DG, Gouvea Bogossian E, Brasil S, Cardim D, Czosnyka M, et al
Critical CareAdult
Read the full paper free at PubMed Central ↗

Abstract

Despite invasive methods are the gold standard for intracranial pressure (ICP) measurement, several non-invasive techniques (nICP) have been proposed as surrogate, although their use remains insufficiently recognized in clinical practice. These include transcranial Doppler blood flow velocity  assessment (arterial or venous), optic nerve sheath diameter (ONSD), automated pupillometry, measurement of skull expansion and compliance, brain imaging, double-depth ophthalmic artery blood flow velocity, and ultrasound time-of-flight. The main limitations of all indirect methods are calibration and zeroing, which constrain the absolute accuracy of non-invasive ICP monitoring. For transcranial Doppler-based methods, the 95% limits of agreement are approximately ± 7-15 mmHg, while for ONSD-based techniques they range from ± 7-10 mmHg. Improved predictive accuracy may be achieved by combining different modalities and applying advanced signal analysis techniques. Importantly, in patients with acute brain injury, nICP can complement invasive monitoring by guiding patient selection for urgent monitoring, facilitating brain assessment in moderate traumatic brain injury, and assisting management in patients with coagulopathy. In the general intensive care population, nICP may provide valuable information after cardiac arrest, liver failure, and sepsis. In the emergency department, early detection of intracranial hypertension helps prevent missing the "golden hour" of brain care. Finally, nICP is particularly relevant in low-resource settings, where intensive care facilities are limited.

More on this topic

Hypertension

Subject terms

Humans; Intracranial Pressure; Intensive Care Units; Ultrasonography, Doppler, Transcranial; Monitoring, Physiologic; Optic Nerve; Intracranial Hypertension; Critical Care; Blood Flow Velocity

DOI: 10.1007/s00134-026-08420-7 · PubMed: 42043555

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Picetti E, Biasucci DG, Gouvea Bogossian E, et al. Non-invasive intracranial pressure estimation in the intensive care unit: narrative review of methods and clinical applications. Intensive Care Med. 2026;52(4):747-764. doi:10.1007/s00134-026-08420-7

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Critical Care studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Review · Crit Care · Jul 22, 2026 · Critical Care

Pressure-targeted neurocritical care at the bedside: the emerging role of transcranial doppler

Randomized trial · Crit Care · May 28, 2026 · Critical Care, Anesthesiology

Early inhaled isoflurane matched propofol for sedation in neurocritical patients

Research · Crit Care · May 9, 2026 · Critical Care, Neurology

Intracranial compliance monitoring using pulse shape index in traumatic brain injury: relation to cerebral physiology and clinical outcome

Research · Crit Care · Mar 11, 2026 · Critical Care, Neurology

A noninvasive method for assessing optimal cerebral perfusion pressure

Review · Intensive Care Med · Apr 20, 2026 · Critical Care, Neurology

Temperature control in acute brain injury