Background Rapid expansion of transcatheter structural heart interventions has increased occupational radiation exposure for interventional echocardiographers (IEs). Objectives The authors aimed to quantify real-time underlead pelvic and chest-level radiation exposure to IEs during left atrial appendage occlusion (LAAO), transcatheter mitral valve intervention (TMVI), and transcatheter tricuspid valve intervention (TTVI); estimate implications for fetal safety; and identify independent predictors of higher chest dose. Methods This prospective, single-center study quantified radiation exposure during 118 LAAO, 59 TMVI, and 53 TTVI procedures from February 2025 to February 2026. Multivariable linear regression on log-transformed chest-level dose identified independent predictors. Comparisons used Kruskal-Wallis, Mann-Whitney U, and Spearman tests. Results Pelvic dose was 0 μSv in 98.7% of cases; estimated dose for full pregnancy was ∼2.3 μSv, well below the recommended limit. Median raw chest-level exposure was 9.0 μSv (IQR: 3.2-21.0) for LAAO, 18.0 μSv (7.5-43.5) for TMVI, and 36.0 μSv (16-116) for TTVI (P < 0.001). IEs received 10- to 50-fold higher doses than sonographers (P < 0.001). Independent predictors of higher chest-level dose were higher log(dose-area product) (1.57; 95% CI: 1.29-1.91), head-of-bed positioning (2.17; 95% CI: 1.06-4.43), TMVI (2.27; 95% CI: 1.44-3.58), and TTVI (2.70; 95% CI: 1.35-5.40) vs LAAO, and half-shield-only use (3.78; 95% CI: 1.51-9.44) (all P ≤ 0.035). Conclusions The near absence of detectable under-lead pelvic radiation with standard lead apparel and shielding provides strong reassurance regarding reproductive safety. IEs sustain higher chest-level radiation exposure during TMVI and TTVI than LAAO. Head-of-bed positioning and half-shield-only use are key modifiable drivers, underscoring the need for standardized full-shielding protocols and positional awareness.

DOI: 10.1016/j.jacadv.2026.102959 · PubMed: 42360239

Cite this article

Wessly P, Haines J, Jimenez E, Howard L, Madalinski B, Jain R. Occupational Pelvic and Chest-Level Radiation Exposure Among Interventional Echocardiographers During Percutaneous Structural Heart Interventions. JACC Adv. 2026. doi:10.1016/j.jacadv.2026.102959

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Cardiology

JACC Adv · Nov 23, 2026 · Research · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

JACC Adv · Nov 20, 2026 · Meta-analysis · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

JACC Adv · Nov 20, 2026 · Research · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Lancet · Nov 19, 2026 · Review · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

JACC · Nov 19, 2026 · Review · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk