Visual abstractsVisuals
ResearchAmerican Journal of Ophthalmology · May 20, 2026

Opacity Detection on Optical Coherence Tomography Based on an Incidence-Angle and Depth-Dependent Model of Corneal Reflectance

Assaf JF, Yazbeck H, Sims D, Hong J, Liu CF, Gunes I, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose To develop and validate an automated corneal opacity detection algorithm for optical coherence tomography (OCT) images, utilizing an incidence-angle- and depth-dependent model of corneal reflectance. Design Retrospective, cross-sectional diagnostic accuracy study. Subjects Training used 95 healthy eyes from 49 volunteers. Testing included 50 eyes from 42 patients with corneal opacities and 35 healthy eyes from 35 volunteers. Methods Normal-eye OCT scans were used to model normative incidence-angle-dependent reflectance across corneal layers. The algorithm detected pixels above the normal reflectance range using model-based thresholds, binned percentile analysis, and morphological operations. Eye-level performance was evaluated against slit-lamp examination as clinical ground truth and compared with 5 trained physician annotators. Pixel-level agreement with consensus annotations (≥3 of 5 annotators) was assessed with Dice similarity coefficient. Main outcome measures Eye-level accuracy, F1-score, sensitivity, and specificity; pixel-level Dice similarity coefficient and segmented-area agreement versus consensus annotations. Results At the eye level, the algorithm achieved accuracy of 0.93, F1-score of 0.94, sensitivity of 0.96, and specificity of 0.89. Human annotators had a mean accuracy of 0.83 ± 0.06, F1-score of 0.85 ± 0.04, sensitivity of 0.84 ± 0.09, and specificity of 0.80 ± 0.27. At the pixel level, mean Dice similarity coefficient versus consensus was 0.58 for the algorithm and 0.71 ± 0.05 for annotators. The algorithm's total segmented opacity area was close to the consensus pixel count (98% of consensus). Conclusion An algorithm that incorporates incidence angle and depth-specific reflectance thresholds detects and segments corneal opacities. It demonstrated favorable accuracy at the eye level and produced quantitative opacity maps on OCT.

Topics

Humans; Tomography, Optical Coherence; Retrospective Studies; Cross-Sectional Studies; Female; Algorithms; Male; Cornea; Adult; Corneal Opacity; Middle Aged; Reproducibility of Results

DOI: 10.1016/j.ajo.2026.05.015 · PubMed: 42167435

Spotted a mistake? Suggest a correction

More in Ophthalmology

ResearchPediatricAm J Ophthalmol · Nov 20, 2026 · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

Association of allergic conjunctivitis severity with meibomian gland abnormalities in children: a cross-sectional study

Randomized trialVisual abstractPediatricJAMA Ophthalmol · Nov 19, 2026 · Ophthalmology

Higher concentration atropine drops slowed myopia progression in children

Low-Concentration Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT2 Randomized Clinical Trial

ResearchAm J Ophthalmol · Nov 19, 2026 · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Smoke, Not Smoking, as a Possible Risk Factor Triggering Conversion in Leber's Hereditary Optic Neuropathy: A Retrospective Case Series

ResearchOphthalmology · Nov 18, 2026 · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Trends and Variation in Uveal Melanoma Management in the National Cancer Database, 2004-2023

ResearchAm J Ophthalmol · Nov 18, 2026 · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients

Developing Static Perimetry Thresholds to Assess Visual Field Loss Severity in Patients with Retinitis Pigmentosa