Visual abstractsVisuals
ResearchInternational Journal of Surgery · Dec 22, 2025

Optimisation strategies for intramedullary nailing parameters in subtrochanteric fractures of the femur: a multimodal assessment based on finite element and biomechanical experiments

Qi X, Li C, Wang J, Zhang Q, Zhang X, Zhang Y, et al
SurgeryAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Subtrochanteric femur fractures account for 40 % of proximal femur fractures, and intramedullary nailing (IMN) is the treatment of choice, but there is a lack of uniformity in the selection of models. The challenge of individualized adaptation of diameter and length needs to be resolved, as too large or too small may lead to a lack of stability or increased surgical risk. Objective To establish a parametric selection model by analyzing the biomechanical properties of IMNs of different specifications to provide a basis for the clinical optimization of implantation strategies. Methods Finite element analysis combined with in vitro biomechanical experiments was used to construct a three-dimensional model based on femur CT data from healthy volunteers to assess the stress distribution and displacement characteristics of 15 sets of IMN (10/11/12 mm in diameter and 280-360 mm in length); a Sawbone artificial bone was used to simulate the Seinsheimer II C fracture, and the strain under axial compression was tested, ultimate load and failure mode. Result The 12 mm diameter IMN performed optimally biomechanically, with lower displacement and stress peaks than the smaller diameter group, but may exacerbate the femoral neck stress masking effect. Nail length had no significant effect on stress. Re-fracture around the locking screws occurred in all groups at a load of 5 kN, suggesting a mechanically weak zone near the fracture line. Conclusion For patients with Seinsheimer type IIC subtrochanteric femoral fractures who have good bone quality and a femoral neck anteversion angle ≤15°, this study proposes a personalized selection strategy using CT-based 3D reconstruction of the narrowest medullary cavity diameter, recommending an anatomically matched intramedullary nail (320 mm length) to optimize both mechanical stability and biological healing. The results provide important theoretical support for clinical precision treatment.

DOI: 10.1097/JS9.0000000000004568 · PubMed: 41427533

Spotted a mistake? Suggest a correction

More in Surgery

Br J Surg · Nov 20, 2026 · Guideline · Surgery

Experts agree on guidelines for radical resection with intestinal autotransplantation for pancreatic cancer

Br J Surg · Nov 20, 2026 · Review · Surgery

Virtual wards used for 27,093 surgical patients in 55 studies

Am J Transplant · Nov 20, 2026 · Guideline · Surgery

Expert panel updates guidance on transplant infections management

Am J Transplant · Nov 19, 2026 · Research · Basic science · Surgery

Human CD47 reduces natural killer cell cytotoxicity on porcine endothelial cells

BJS Open · Nov 18, 2026 · Meta-analysis · Surgery

Experts agree on initial management of oesophageal perforation