Visual abstractsVisuals
ResearchJACC: Advances · Aug 27, 2026

Optimized Balloon-Expandable Transcatheter Aortic Valve Implantation and Clinical Outcomes

Vitez L, Angellotti D, Tomii D, Lanz J, Samim D, Ferro C, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background The expansion of transcatheter aortic valve replacement (TAVR) to younger patients with longer life expectancy requires procedural optimization to enhance long-term valve durability. Objectives To evaluate the relationship between fluoroscopic determinants of optimal transcatheter heart valve (THV) implantation-coaxiality, implantation depth, and expansion-and clinical and valve-related outcomes. Methods In this cohort study, consecutive patients undergoing transfemoral TAVR with balloon-expandable prostheses (Sapien S3, Sapien S3 Ultra) between February 2014 and June 2022 were included. THV coaxiality, implantation depth, and expansion were assessed in the 3-cusp view following deployment using standardized protocols. Suboptimal implantation was defined as ≥1 unfavorable determinants (coaxiality ≥4.8°, depth ≥6 mm, or underexpansion ≥20%). Outcomes included the modified early safety endpoint, moderate or severe hemodynamic valve deterioration, and stage 2 bioprosthetic valve failure. Results Among 1,032 patients (mean age 81 ± 6 years, 35.1% female), suboptimal THV implantation occurred in 443 (42.9%) patients and was driven by noncoaxial deployment (n = 240, 23.3%), excessive implantation depth (n = 261, 25.3%), and underexpansion (n = 54, 5.2%). Suboptimal implantation was associated with a higher likelihood of the modified early safety endpoint at 30 days (43.3% vs 19.9%; adjusted odds ratio: 3.05; 95% CI: 2.30-4.04) and stage 2 bioprosthetic valve failure at 5 years (subHR: 4.40; 95% CI: 1.25-13.59). Patients with ≥2 determinants demonstrated higher rates of hemodynamic valve deterioration at 5 years (subHR: 3.48; 95% CI: 1.24-9.80). Conclusions Optimal THV implantation was associated with improved early procedural safety and long-term THV durability in balloon-expandable TAVR. Systematic fluoroscopic assessment of optimized valve implantation may enhance patient outcomes.

DOI: 10.1016/j.jacadv.2026.103037 · PubMed: 42657851

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology