Visual abstractsVisuals
ResearchResuscitation Plus · Jul 9, 2026

Optimizing automated external defibrillator incremental deployment to improve out-of-hospital cardiac arrest coverage: a spatial optimization study

Cheng P, Luo D, Zhang H, Xu B, Yang P, Xue H, et al
Emergency MedicineCardiologyCritical CareAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Public access defibrillation (PAD) is critical for out-of-hospital cardiac arrest (OHCA) response, yet the effectiveness of existing automated external defibrillator (AED) networks remains limited in many urban settings. Evidence is lacking on how incremental AED deployment translates into coverage gains and when diminishing returns occur, particularly in resource-constrained cities. Methods A retrospective spatial analysis was conducted using Utstein-compliant OHCA registry data from Haikou City, China (2015-2021). AED coverage was assessed using Euclidean distance across response radii of 100-500 m. Incremental AED deployment was simulated using the maximal covering location problem (MCLP) model while holding the existing network fixed. Changes in coverage, marginal gains, saturation thresholds, and optimized location types were evaluated using geographic information system methods. Results Among 5792 eligible OHCA events, baseline AED coverage was limited (14.6% within 100 m; 45.7% within 500 m). Incremental deployment produced rapid early coverage gains across all distance thresholds, followed by diminishing marginal returns and eventual saturation. Near-saturation required substantially more AEDs at shorter radii (approximately 1467 additional devices at 100 m) compared with larger radii (308-499 devices at 300-500 m). Optimized deployment shifted priority toward restaurants and commercial/industrial settings, while home or private residence, transportation hubs, and government/educational institution yielded lower marginal gains despite hosting most existing AEDs. Conclusions Existing AED networks provide limited OHCA coverage due to spatial mismatch between placement and demand. MCLP-guided deployment shows early gains but diminishing returns, supporting phased, locally-calibrated expansion that maximizes effective emergency access, especially in resource-constrained settings.

DOI: 10.1016/j.resplu.2026.101408 · PubMed: 42500307

Cite this article

Cheng P, Luo D, Zhang H, Xu B, Yang P, Xue H. Optimizing automated external defibrillator incremental deployment to improve out-of-hospital cardiac arrest coverage: a spatial optimization study. Resusc Plus. 2026. doi:10.1016/j.resplu.2026.101408

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Emergency Medicine

J Med Internet Res · Nov 23, 2026 · Meta-analysis · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

BMJ Med · Nov 18, 2026 · Research · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Am J Emerg Med · Nov 13, 2026 · Research · Emergency Medicine, Hematology

ED red blood cell transfusion linked to longer hospital stays in severe anemia

J Med Internet Res · Nov 13, 2026 · Research · Digital Health & AI, Emergency Medicine

Physicians often intend to act on false information in AI-generated abstracts

Am J Emerg Med · Nov 12, 2026 · Research · Emergency Medicine, Neurology

Serum lactate levels differed across neurologic emergencies in emergency patients