Pacemaker Implantation Rates With the Self-Expandable Navitor Valve
Abstract
Background
Transcatheter aortic valve replacement using self-expandable valves requires permanent pacemaker implantation (PPI) more often compared with balloon-expandable systems. The Navitor prosthesis is a novel, tubular-shaped self-expandable valve with increasing use. Methods
Thirty-day PPI rates were compared between 148 patients treated with the Navitor system and 165 patients treated with the Evolut system. Patients with preexisting PPI, high-risk ECG (right bundle-branch block), and Navitor 35-mm/Evolut 34-mm prostheses were excluded. Multivariable logistic regression was used to adjust for baseline differences. Results
Patients treated with Navitor were older (83.0 [IQR, 78-86] versus 81.0 [IQR, 76-84] years; P Conclusions
Depending on prosthesis size, transcatheter aortic valve replacement with the Navitor system may have PPI rates comparable to other self-expandable valves. High implantation of the Navitor may be attempted to reduce PPI rates.
Topics
Spotted a mistake? Suggest a correction
More in Cardiology
Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations
Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis
Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately
Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms
Spontaneous coronary artery dissection affects younger women more often than expected
Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research
Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk
Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology