Patient-Specific Computational Flow Simulation Reveals Adverse Hemodynamic Factors Associated With Occlusion of Directional Branches After Fenestrated-Branched Endovascular Aneurysm Repair
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Fenestrated and branched endovascular aneurysm repair can be complicated by branch vessel occlusion in the absence of structural stenosis. We hypothesized that computational flow simulation could identify adverse hemodynamic features associated with postfenestrated and branched endovascular aneurysm repair branch occlusion. Methods
Patients undergoing 4-vessel fenestrated and branched endovascular aneurysm repair for Extent II to IV thoracoabdominal aortic aneurysms were retrospectively reviewed. Branches that occluded without identifiable kinking or stenosis on computed tomography were included, along with an equal cohort of anatomy-matched patent controls. Patient-specific pulsatile rigid-wall simulations were performed using SimVascular with individualized geometries and boundary conditions. Abnormal time-averaged wall shear stress (TAWSS) was defined as 70 dynes/cm2. Results
Nine patients (36 target vessels) experienced 10 branch occlusions. Postoperative pressure and flow did not differ significantly between occluded and patent renal or mesenteric branches. However, occluded renal and mesenteric branches demonstrated significantly larger postoperative areas of abnormal TAWSS compared with controls (renal: 14.5% versus 5.9%, P=0.003; mesenteric: 17.7% versus 9.9%, P=0.035). Logistic generalized estimating equation modeling showed abnormal TAWSS to be a significant predictor of renal branch occlusion (P=0.0085). Model estimates suggested occlusion probabilities of 1.1%, 31%, and 94% at 0%, 10%, and 20% abnormal TAWSS surface area, respectively. A cluster-bootstrapped receiver operating characteristic curve (area under the curve, 0.876) identified a >10.2% threshold that correctly classified 92% of renal occlusions. Abnormal TAWSS frequently localized to distal stent-artery interfaces. Conclusions
Elevated abnormal TAWSS within stented renal branches is associated with subsequent branch occlusion after fenestrated and branched endovascular aneurysm repair. Computational flow simulation-derived TAWSS thresholds may help identify high-risk branches before failure, warranting prospective validation.
Topics
Spotted a mistake? Suggest a correction
More in Cardiology
Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations
Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis
Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately
Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms
Spontaneous coronary artery dissection affects younger women more often than expected
Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research
Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk
Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology