Visual abstractsVisuals
ResearchJPRAS Open · Jul 7, 2026

Patient-specific implants are more stable than conventional miniplates in Le Fort I osteotomy in patients with clefts

Rouhiainen V, Heliövaara A, Leikola J, Suojanen J, Juuri E
Plastic & Reconstructive SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Introduction Virtual surgical planning (VSP) and patient-specific implants (PSI) have become standard in orthognathic surgery, demonstrating accuracy and stability comparable with miniplates. Aims To compare postoperative skeletal stability of Le Fort I osteotomy using VSP with PSIs versus conventional cast model surgery with miniplate fixation in patients with clefts. Methods Retrospective analysis of lateral cephalograms and medical records of patients who underwent Le Fort I osteotomy between 2017 and 2023 at the Cleft Palate and Craniofacial Center, Helsinki University Hospital. Horizontal and vertical surgical advancement and relapse were assessed by superimposing preoperative, immediate, and one-year postoperative cephalometric tracings. Statistical analyses included independent samples t-, Mann-Whitney U-, Chi-squared and Fischer's exact test. Results Fifty-nine non-growing patients with cleft lip and/or palate (29 males; median age 18.9 years) were categorized into two groups based on the fixation method (19 PSI, 40 miniplate). Mean maxillary advancement was greater with PSIs than miniplates (7.1 mm vs. 4.3 mm; p < 0.001). Mean vertical movement was -0.8 mm with PSIs vs. -3.8 mm with miniplates (p < 0.001), reflecting more impactions in the PSI group. Horizontal and vertical relapses were significantly smaller in the PSI group (horizontal: 0.28 mm vs. 0.9 mm, 4% vs. 21% of advancement; p < 0.001; vertical: 0.81 mm vs. 1.6 mm, 30% vs. 41% of movement; p = 0.004). Horizontal advancement correlated with relapse only with miniplates (r = 0.329, p = 0.038). Conclusions PSI fixation in cleft Le Fort I osteotomy seems to provide greater horizontal and vertical stability than miniplates.

DOI: 10.1016/j.jpra.2026.07.010 · PubMed: 42565001

Cite this article

Rouhiainen V, Heliövaara A, Leikola J, Suojanen J, Juuri E. Patient-specific implants are more stable than conventional miniplates in Le Fort I osteotomy in patients with clefts. JPRAS Open. 2026. doi:10.1016/j.jpra.2026.07.010

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Plastic & Reconstructive Surgery

Plast Reconstr Surg Glob Open · Nov 20, 2026 · Research · Plastic & Reconstructive Surgery

Autologous fat grafting improved radiation-induced skin changes in breast cancer patients

Plast Reconstr Surg Glob Open · Nov 20, 2026 · Research · Plastic & Reconstructive Surgery

Most cardiothoracic surgeons use wire cerclage for sternal closure, not rigid plate fixation

Plast Reconstr Surg Glob Open · Nov 20, 2026 · Research · Plastic & Reconstructive Surgery

Mailbox flap mastopexy technique corrects ptosis in 90.5% of patients

Plast Reconstr Surg Glob Open · Nov 20, 2026 · Research · Plastic & Reconstructive Surgery, Surgery

Surgical treatment satisfies patients with tuberous breast deformity regardless of psychiatric history

Plast Reconstr Surg Glob Open · Nov 20, 2026 · Research · Plastic & Reconstructive Surgery

Urethral strictures and fistulas common after phalloplasty surgery