Visual abstractsVisuals
ResearchJournal of the American Heart Association · Jul 25, 2026

Percutaneous Pacemaker Lead Implantation in Patients With Univentricular Circulation and Selected Patients With Biventricular Circulation: Intracavitary and Intramyocardial Approaches

Gendera K, Kolb C, Janoušek J, Georgiev S, Borgmann K, Heinisch PP, et al
CardiologyAdult and pediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Epicardial pacemaker lead implantation in patients with univentricular circulation following total cavopulmonary connection with an extracardiac conduit and without fenestration necessitates median sternotomy. Transvenous access, although possible and previously described, may be technically challenging in this population and carries an increased risk of lead-related thrombosis within the subsystemic atrium or ventricle. Surgical implantation usually requires mechanical ventilation and is associated with procedural morbidity. A percutaneous approach represents a minimally invasive treatment option that can be applied in this subgroup and in selected patients with biventricular circulation. We report on 9 patients in whom a pacemaker lead was implanted percutaneously with the use of a puncture sheath. Methods Patients with pacemaker indications and anatomic constraints precluding conventional transvenous access underwent computed tomographic imaging for procedural planning. Eight patients had single-ventricle physiology, and 1 patient had biventricular circulation with severely impaired ventricular function. Results Percutaneous pacemaker lead implantation was successful in all 9 patients. The median age was 11.2 (range, 6.0-43.8) years, and median weight was 22.0 (range, 19.9-68.5) kg. In 6 patients, the puncture was performed via the subxyphoidal approach, in 1 patient via the transthoracic approach, and in 2 patients, venous access was used (subclavian vein, n=1; internal jugular vein, n=1). The median follow-up time was 26.5 (range, 0.1-64.8) months. Only 1 patient required reintervention for lead dysfunction after 26 months; in all others, lead thresholds remained stable. Conclusions Percutaneous intramyocardial and intracavitary pacemaker lead implantation is feasible and may obviate the need for surgery. However, in selected cases, identifying a suitable landing zone may be challenging due to prior surgical interventions, scarring, or fibrosis.

Topics

Humans; Pacemaker, Artificial; Female; Child; Treatment Outcome; Male; Adolescent; Adult; Young Adult; Cardiac Pacing, Artificial; Tomography, X-Ray Computed; Heart Defects, Congenital

DOI: 10.1161/JAHA.125.048577 · PubMed: 42500872

Spotted a mistake? Suggest a correction

More in Cardiology

JACC Adv · Nov 23, 2026 · Research · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

JACC Adv · Nov 20, 2026 · Meta-analysis · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

JACC Adv · Nov 20, 2026 · Research · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Lancet · Nov 19, 2026 · Review · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

JACC · Nov 19, 2026 · Review · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk