ResearchInternational Journal of Surgery · Mar 17, 2026

Performance evaluation of electrosurgical pencils: insights into surgical smoke mitigation and thermal damage reduction

Sang K, Kong Y, Lee JK, Na HY, Yu HW, Choi JY
SurgeryAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Electrosurgical pencils (ESPs) are essential in modern surgery; however, concerns remain regarding their exposure to surgical smoke and thermal tissue damage. This study quantitatively evaluated four ESPs with a particular focus on two critical aspects: surgical smoke generation and minimization of thermal damage to the surrounding tissues. Methods Full-thickness incisions were made on the porcine dorsal skin using six instruments: scalpel, uncoated Bovie, coated Bovie, PlasmaBlade, and Duoblade (with and without suction). Surgical smoke was measured by particle counting, blood loss was quantified, and histological analyses (hematoxylin and eosin, Masson's trichrome, CD3, and α-smooth muscle actin staining) were performed to assess the wound scar width and densities of CD3-positive lymphocytes and myofibroblasts. Results Duoblades, especially those with suction, consistently produced the lowest level of surgical smoke, reducing particle counts by up to 96.1% compared to the uncoated Bovie. It also achieved the greatest reduction in blood loss (93.3% less than that of the scalpel) and resulted in the narrowest scar width among the ESPs. The wound scar width and densities of CD3-positive lymphocytes and myofibroblasts were reduced more rapidly in Duoblade-incised wounds than in those with other ESPs. Discussion Device design and energy delivery significantly affect the surgical smoke and tissue outcomes. Duoblade dielectric heating and integrated suction provide superior environmental safety and wound healing, while maintaining excellent hemostasis. The Duoblade has a suction function that reduces the surgical smoke.

DOI: 10.1097/JS9.0000000000005093 · PubMed: 42682399

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Sang K, Kong Y, Lee JK, Na HY, Yu HW, Choi JY. Performance evaluation of electrosurgical pencils: insights into surgical smoke mitigation and thermal damage reduction. Int J Surg. 2026. doi:10.1097/JS9.0000000000005093

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Surgery studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

More in Surgery

Research · J Otolaryngol Head Neck Surg · Nov 25, 2026 · ENT (Otolaryngology), Surgery

Preemptive artery management linked to less bleeding in hypopharyngeal cancer surgery

Research · J Otolaryngol Head Neck Surg · Nov 24, 2026 · ENT (Otolaryngology), Surgery

Survey of Canadian surgeons shows small workforce with limited specialized training and long wait times

Research · BJS Open · Nov 24, 2026 · Surgery, Oncology

Early-onset colorectal cancer survivors were linked to higher rates of sexual dysfunction

Research · BJS Open · Nov 24, 2026 · Surgery, Oncology

High faecal immunochemical test results were associated with increased proximal gastrointestinal cancer risk

Systematic review · BJS Open · Nov 24, 2026 · Surgery

International guidelines agree on selective antibiotic use but differ on many diverticulitis management strategies