Performance of a Sepsis Prediction Model Across Different Sepsis Definitions
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Importance
Early detection of sepsis improves clinical outcomes, but the Early Detection of Sepsis Model, version 1 (Epic Systems Corp) has shown poor performance. Comparing sepsis models is complicated by varying outcome definitions and limited generalizability outside the development site. Objective
To evaluate the Early Detection of Sepsis Model, version 2 using multiple standard sepsis definitions. Design, setting, and participants
This diagnostic study included all adult (aged ≥18 years) encounters from emergency departments, inpatient units, intensive care units, and perioperative areas across 9 acute care hospitals between March 17 and August 31, 2024. The locally trained gradient-boosted tree ensemble sepsis model, incorporating patient demographics, vital signs, laboratory results, medication administration, and other clinical features, generated predictions every 15 minutes. Model performance was evaluated against 3 electronically computable sepsis definitions: the Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3); Centers for Medicare & Medicaid Services Severe Sepsis and Septic Shock: Management Bundle (SEP-1); and the Centers for Disease Control and Prevention Adult Sepsis Event (ASE). Exposure
Silent deployment of the sepsis model. Main outcomes and measures
Model performance metrics included discrimination, as measured using the area under the receiver operating characteristic curve (AUROC), and precision, as measured by the area under the precision-recall curve (AUPRC). Test characteristics and potential lead-time warning were evaluated over a range of model score thresholds. Results
Among 198 494 patient encounters (median [IQR] age, 55 [36-71] years; 54.8% female) the incidence of sepsis varied by outcome definition. A total of 5832 encounters (2.9%) met the Sepsis-3 definition, 2366 (1.2%) met the SEP-1 definition, and 3881 (2.0%) met the ASE definition. The AUROC and AUPRC were, respectively, 0.89 (95% CI, 0.89-0.90) and 0.24 (95% CI, 0.23-0.25) for Sepsis-3, 0.94 (95% CI, 0.94-0.94) and 0.16 (95% CI, 0.15-0.17) for SEP-1, and 0.85 (95% CI, 0.85-0.86) and 0.11 (95% CI, 0.11-0.12) for ASE. In the overall study population, the Youden top left threshold for the Sepsis-3 outcome definition was 9, which yielded a positive predictive (PPV) of 11.4% (95% CI, 11.1%-11.7%) and median lead time of 3.4 hours (IQR, 0.9-22.3 hours). The SEP-1 had a PPV of 6.8 (95% CI, 6.6-7.1 9.9) and median (IQR) lead time of 4.5 (4.3-23.1) hours, and the ASE had a PPV of 5.9 (95% CI, 5.7-6.0) and median (IQR) lead time of 1.4 (0.5-14.8) hours. Conclusions and relevance
This cohort study found that the locally trained sepsis model showed moderate predictive performance, with discrimination, precision, and lead time varying considerably by the sepsis definition applied. Although the model provided some advance warning before sepsis onset, a high false-positive rate may limit its clinical utility without careful threshold selection and tailored implementation.
Topics
Cite this article
Dutta S, McMurry R, Tasi MC, Dunham L, McEvoy DS, Stump T. Performance of a Sepsis Prediction Model Across Different Sepsis Definitions. JAMA Netw Open. 2026. doi:10.1001/jamanetworkopen.2026.5599
Spotted a mistake? Suggest a correction