ResearchDiabetes, Obesity and Metabolism · Jan 2, 2026

Performance of continuous glucose monitoring systems (CGMs) during commercial flights in T1DM: A within-subject comparative pilot study

Meçani R, Basta S, Baumann PM, Cigler M, El Hakouni O, Hochfellner DA, et al
Endocrinology & DiabetesAdult
Read the full paper free at PubMed Central ↗

Abstract

Aims Continuous glucose monitoring (CGM) systems are increasingly used, but their accuracy under flight-conditions remains insufficiently studied. We assessed sensor accuracy of four CGMs during in-flight (mid-haul) and ground conditions. Materials and methods Participants (n = 20) wore four sensors (Abbott Libre 3, Dexcom G7, Medtronic Simplera, and Sinocare iCan i3) in parallel, inserted 1 day prior to experiment. Capillary reference measurements were performed every 30 min. Accuracy evaluation included: proportion of CGM values within 10% of comparator glucose levels >100 mg/dL or within 10 mg/days of comparator levels ≤100 mg/dL (%10/10), along with %20/20 agreement rates, mean absolute relative difference (MARD), Consensus error grid. Results Twenty participants with type 1 diabetes (age: 37.9 ± 12.8 years, HbA1c: 52.3 ± 4.9 mmol/mol, diabetes duration 19.25 ± 10.6 years) were included in the analysis. Data from 297 sensors with 3473 matched pairs (G7/Libre3/Simplera/i3) were analysed. The overall MARDs were: 9.5% ± 3.3% (G7), 9.6% ± 3.8% (Libre3), 19.9% ± 6.2% (Simplera) and 15.7% ± 6.6% (i3). Overall %20/20 and %10/10 agreement rates were 90.6%/70.2% (G7), 90.8%/66.8% (Libre3), 63.6%/37.8% (Simplera) and 72.5%/42.2% (i3) respectively. The proportion of values in Zones A and B of the Consensus error grid was 98.9% (G7), 99.0% (Libre 3), 94.5% (Simplera) and 97.5% (i3). Prandial state and flight phase had limited influence on the relative performance ranking of the devices. Conclusions G7 and Libre3 showed consistently higher accuracy and clinical reliability across various phases of flight and ground conditions. Simplera and i3 exhibited greater variability in accuracy. These findings suggest that while modern CGMs could support diabetes management in aviation, individual system performance may differ under specific operational conditions.

Subject terms

Humans; Diabetes Mellitus, Type 1; Blood Glucose Self-Monitoring; Male; Female; Pilot Projects; Adult; Blood Glucose; Middle Aged; Reproducibility of Results; Glycated Hemoglobin; Aircraft

DOI: 10.1111/dom.70418 · PubMed: 41480660

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Meçani R, Basta S, Baumann PM, et al. Performance of continuous glucose monitoring systems (CGMs) during commercial flights in T1DM: A within-subject comparative pilot study. Diabetes Obes Metab. 2026;28(3):2245-2254. doi:10.1111/dom.70418

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Endocrinology & Diabetes studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Review · Diabetologia · Mar 9, 2026 · Endocrinology & Diabetes

Continuous glucose monitoring as a tool in early-stage type 1 diabetes

Research · Nat Med · May 3, 2024 · All ages · Endocrinology & Diabetes

Equitable implementation of a precision digital health program for glucose management in individuals with newly diagnosed type 1 diabetes

Randomized trial n = 52 · Diabetes Obes Metab · May 25, 2022 · Endocrinology & Diabetes, Gastroenterology & Hepatology

Liver-targeted insulin was associated with fewer low blood sugar events in people with type 1 diabetes

Guideline · Diabetes Care · Jul 20, 2023 · Endocrinology & Diabetes

New guidelines clarify which lab tests diagnose and monitor diabetes

Secondary analysis of a trial · Diabetes Obes Metab · Mar 15, 2021 · Endocrinology & Diabetes

Dapagliflozin added to insulin therapy was associated with better glucose control in Japanese patients