What is the accuracy of stool-based molecular tests for paediatric tuberculosis diagnosis?
Who
Children younger than 16 years with presumptive tuberculosis
Compared
0·60Stool Xpert (95% CI 0·48-0·71)
0·73Stool Xpert Ultra (0·63-0·81)
0·44Other in-house molecular methods (0·29-0·60)
Main outcome
Sensitivity using any bacteriological confirmation as the reference standard
Result: stool Xpert Ultra sensitivity 0·73 (95% CI 0·63-0·81)
Bottom line: Stool-based Xpert Ultra improves bacteriological confirmation of tuberculosis in children, especially when using centrifuge-free simplified processing methods.
Funded by: EDCTP2 programme and European Society of Pediatric Infectious Diseases
Clinical question: What is the accuracy of stool-based molecular tests for paediatric tuberculosis diagnosis?
Why it matters: It is unknown how accurate stool-based molecular tests are for diagnosing tuberculosis in children and how different processing methods affect these results.
Key points
Researchers analyzed 35 studies involving children under 16 years old to evaluate how well molecular tests in stool samples detect tuberculosis.
When compared to any bacteriological confirmation from respiratory samples, stool Xpert Ultra had a sensitivity of 0.73 (95% CI 0.63-0.81).
Using centrifuge-free stool processing methods was associated with a higher stool Xpert Ultra sensitivity of 0.77 (95% CI 0.66-0.85) compared to 0.61 (95% CI 0.41-0.78).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Carratalà-Castro L, Munguambe S, Saavedra-Cervera B, de Haas P, Kay A, Marcy O. Performance of stool-based molecular tests and processing methods for paediatric tuberculosis diagnosis: a systematic review and meta-analysis. Lancet Microbe. 2024. doi:10.1016/j.lanmic.2024.100963