Visual abstractsVisuals
ResearchDiabetes, Obesity and Metabolism · Dec 19, 2025

Performance of three simultaneously used rtCGM systems around a physically active weekend camp in adults with type 1 diabetes: A prospective lab and real-world study

Sanfilippo S, Thurm U, Renfordt M, Schierbauer J, Sourij H, Zimmermann P, et al
Endocrinology & DiabetesAdult
Read the full paper free at PubMed Central ↗

Abstract

Aims Real-time continuous glucose monitoring (rtCGM) is crucial to diabetes management in type 1 diabetes (T1D), but its accuracy decreases during glucose fluctuations triggered by physical activity and exercise. Materials and methods Twenty adults with T1D (9 females; age 50 ± 12 years; HbA1c 6.6 ± 0.5%) participated in this study, which included a 3-day lab phase where three group exercise sessions (each lasting 90 min) were performed, followed by a 4-day home phase. Participants were required to wear a Dexcom G7 (Dexcom), FreeStyle Libre 3 (Abbott), and Simplera (Medtronic) rtCGM simultaneously. From 8:00 AM (initial measurement) to 10:00 PM (final measurement), duplicate capillary blood glucose measurements were taken at 2-h intervals using the Contour Next One glucometer (Ascensia Diabetes Care) and recorded in addition to the actual displayed sensor glucose values. The performance of the rtCGM systems was evaluated by means of median absolute relative difference (MedARD) and interquartile range [IQR] against the reference blood glucose. Absolute relative differences (|ARD|) of the three rtCGMs were analysed using the Kruskal-Wallis test (p Results Overall, the MedARD [IQR] for Dexcom G7 was 8.4% [3.6-14.0] (723 comparison points), for Libre 3 7.5% [3.1-13.4] (723 comparison points), and Simplera 13.8% [6.9-22.5] (719 comparison points). No significant differences were found between Libre 3 versus Dexcom G7 (p = 0.35). A significant difference was found for Dexcom G7 versus Simplera and Libre 3 versus Simplera (p Conclusions Dexcom G7 and FreeStyle Libre 3 showed very high accuracy, which could not be found for the Simplera rtCGM system. Clinical registration German Clinical Trial Register, DRKS: DRKS00035836.

Topics

Humans; Diabetes Mellitus, Type 1; Female; Male; Blood Glucose Self-Monitoring; Adult; Middle Aged; Blood Glucose; Exercise; Prospective Studies; Glycated Hemoglobin; Hypoglycemic Agents

DOI: 10.1111/dom.70369 · PubMed: 41417319

Spotted a mistake? Suggest a correction

More in Endocrinology & Diabetes

BMJ Open Diabetes Res Care · Nov 19, 2026 · Research · Endocrinology & Diabetes

Hyperglycemia in pregnancy not linked to fetal overgrowth in Malawi study

Thyroid · Nov 18, 2026 · Research · Endocrinology & Diabetes

Combination therapy normalized fT3 levels in simulated hypothyroid patients

Thyroid · Nov 18, 2026 · Research · Endocrinology & Diabetes

Deep learning model predicts lymph node metastasis in thyroid cancer patients

J Endocr Soc · Nov 17, 2026 · Research · Endocrinology & Diabetes

Gluten-free diet had no impact on glycemia or quality of life in type 1 diabetes patients

BMJ Open Diabetes Res Care · Nov 13, 2026 · Research · Endocrinology & Diabetes

DPP4 inhibitors linked to higher angioedema risk than SGLT2 inhibitors