Visual abstractsVisuals
ResearchERJ Open Research · Mar 9, 2026

Personalised screening intensity based on existing lung cancer risk and spirometry

Goodley P, Zahed H, Balata H, Alonso A, Sharman A, Merchant Z, et al
PulmonologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Existing targeted lung cancer screening programmes are either annual or biennial. We tested the hypothesis that existing risk models can inform personalised screening intervals to improve cost-effectiveness and reduce interval cancers. Spirometric airflow obstruction is a biomarker of lung cancer risk available in some cohorts, so we also explored whether this could add predictive value for stratification. Methods We tested the performance of risk models to predict next-round risk among baseline-negative participants in annual screening in Manchester and National Lung Screening Trial (NLST) cohorts. Models were adapted in the Eastern Cooperative Oncology Group and American College of Radiology Imaging Network (ECOG-ACRIN) sub-study of the NLST to investigate whether incorporating the spirometric percentage of predicted forced expiratory volume in 1 second (FEV1 % pred) improved discrimination and screening efficiency at next-round screens. Results In Manchester, where a Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial model 2012 (PLCOm2012) score of >1.51% was used to determine eligibility, cancer was detected in 1.1% of those with a negative baseline scan after a 1-year interval (45 out of 4136), and in 2.5% of those with a risk of ≥6% (27 out of 1082). The same trend was seen in the NLST, but with lower risk overall. The PLCOm2012 model discriminated next-round risk with an area under the curve (AUC) of 0.72 (95% CI 0.65-0.79), whereas the Lung Cancer Risk Assessment Tool + CT model for negative CT results (LCRAT+CTneg) was potentially superior, with an AUC of 0.75 (95% CI 0.68-0.82) on external validation. The addition of FEV1 % pred as a predictor variable modestly improved discrimination (ΔAUC 0.01-0.04). Discussion Baseline risk could be used to extend intervals for substantial numbers of lower-risk participants, thereby reducing cost and screening harms, while focusing resources on those at highest risk to avoid delayed detection. Adding FEV1 % pred is unlikely to meaningfully contribute to next-round risk prediction.

DOI: 10.1183/23120541.00974-2025 · PubMed: 41809861

Spotted a mistake? Suggest a correction

More in Pulmonology

Eur Respir J · Nov 23, 2026 · Review · Pulmonology

BMP-9 and BMP-10 regulate pulmonary vascular resilience through complex pathways

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Needle aspiration reduced hospital stay by nearly five days for pneumothorax patients

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Inhaled itraconazole improved lung function and asthma control at 40mg dose

Chest · Nov 21, 2026 · Research · Pulmonology

Association between exertional dyspnea and insomnia in a population-based cohort

Chest · Nov 21, 2026 · Research · Pulmonology

Combination therapy reduces obstructive sleep apnea severity by roughly half