Pilot Study: Precision in Plastic Surgery: Efficacy of Nerve Mapping and Neural Stimulation for Facial Nerve Localization in Permanent Filler Removal
Abstract
Background
The surgical removal of permanent facial fillers is often complicated by chronic inflammation, tissue distortion, and the risk of facial nerve injury. This pilot case series highlighted the use of intraoperative nerve monitoring (IONM) to enhance the safety and precision of filler removal procedures. Methods
This single-center pilot case series included patients who underwent permanent facial filler removal using IONM to localize and protect the facial nerve branches. Results
Four female patients (mean age 53 y; range: 48-56 y) underwent surgical removal of permanent facial fillers, with concurrent face lifting and intraoperative facial nerve monitoring. Indications included recurrent infection in 2 (50.0%) patients, chronic inflammation in 1 (25.0%) patient, and facial asymmetry in 1 (25.0%) patient. No patients had preoperative facial nerve deficits. The mean operative time was 4.5 hours, and filler removal was successful in all cases. Facial nerve function was preserved in all patients without any transient or permanent dysfunction. Two patients (50.0%) received adjunctive fat grafting (mean volume 20 mL; range: 16-25 mL). Minor complications occurred in 2 (50.0%) patients and resolved spontaneously in both. All patients (100%) reported improved facial contour and resolution of symptoms. Follow-up ranged from 5 to 12 months, with no recurrence of nodules, inflammation, or occurrence of any nerve dysfunction. Conclusions
This pilot case series showed that surgical removal of permanent facial fillers with IONM proved safe and effective, yielding full nerve preservation, high patient satisfaction, and no major complications. However, this approach needs further study to prove its efficacy, safety, and cost-effectiveness.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training