Larger aortic neck diameter increases risk of type 1a endoleak after EVAR
Pre-operative Aortic Neck Characteristics and Post-operative Sealing Zone as Predictors of Type 1a Endoleak and Migration After Endovascular Aneurysm Repair: A Systematic Review and Meta-Analysis
Clinical question: Do aortic neck characteristics and sealing zone predict type 1a endoleak and migration?
Why it matters: The predictive value of aortic neck characteristics for type 1a endoleak and migration after EVAR was unknown
- Thirty-three studies with EVAR patients were analyzed for neck characteristics and outcomes.
- Larger neck diameter was linked to increased risk of total type 1a endoleak with OR 3.32.
- Angulated neck also increased risk of total type 1a endoleak with OR 4.27.
Limitation the authors note: The analysis was limited by a small number of studies with serious limitations and considerable variability in reporting
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Zuidema R, van der Riet C, El Moumni M, Schuurmann RCL, Ünlü Ç, de Vries JPM. Pre-operative Aortic Neck Characteristics and Post-operative Sealing Zone as Predictors of Type 1a Endoleak and Migration After Endovascular Aneurysm Repair: A Systematic Review and Meta-Analysis. Eur J Vasc Endovasc Surg. 2022. doi:10.1016/j.ejvs.2022.08.017