Abstract

Supine breast MRI offers easier comparison with other screening methods than the prone MRI, but is often impaired by respiratory artifacts. This study aims to identify a suitable acceleration technique for motion-corrected supine breast MRI with a dedicated wearable coil (BraCoil), and to assess the quality of the resulting images. This prospective, single-center study included ten healthy female volunteers. Supine breast MRI was acquired using the BraCoil equipped with seven accelerometers. The acquisition protocol included unenhanced T1- and T2-weighted sequences; 2-, 3-, and 4-fold acceleration, as well as "elliptical scanning", were tested for T1-weighted images. Image reconstruction was performed using two methods: the manufacturer's standard algorithm and an advanced nonrigid motion correction algorithm. The images were compared to each other and to conventional prone MRI via radiological scoring. Additionally, comparisons were made with supine breast MRI obtained using a multi-purpose torso coil reported in previous studies. This study showed that using 2-fold acceleration was optimal for motion-corrected supine breast MRI using the BraCoil. It also demonstrated that enabling the "elliptical scanning" would shorten the measurement time by 33% without compromising image quality. Finally, for the data acquired, the BraCoil provides superior motion-corrected image quality compared to the torso coil. KEY POINTS: BraCoil image quality outperforms the body coil for both uncorrected and motion-corrected images in supine acquisition for T1w and T2w sequences. Enabling the "elliptical scanning" in T1-weighted sequences does not impair image quality while shortening the measurement time by 33% (compared to the same sequence without enabling this option). A 2-fold acceleration for the T1-weighted sequence provides sufficient scan time reduction, whereas higher acceleration would lead to even shorter scan time at the cost of significantly lower image quality.

Subject terms

Humans; Female; Magnetic Resonance Imaging; Supine Position; Adult; Breast; Prospective Studies; Wearable Electronic Devices; Accelerometry; Motion; Artifacts; Algorithms

DOI: 10.1186/s41747-025-00662-2 · PubMed: 41428163

Cite this article

Megel A, Isaieva K, Nohava L, et al. Preliminary evaluation of image quality in supine breast MRI using a dedicated wearable coil and accelerometer-based motion correction. Eur Radiol Exp. 2025. doi:10.1186/s41747-025-00662-2

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Research · Eur Radiol · Apr 2, 2026 · Pediatric · Radiology & Imaging, Pediatrics

Deep learning improves image quality in motion-robust and sedation-free pediatric brain MRI

Randomized trial · Neurorehabil Neural Repair · Jul 10, 2025 · Physical Medicine & Rehabilitation, Neurosurgery

Wearable sensors detected changes in energy expenditure but not clinical motor scores in spinal cord injury trial

Research · Nat Med · Jan 19, 2023 · Digital Health & AI

A wearable motion capture suit and machine learning predict disease progression in Friedreich's ataxia

Randomized trial · J Med Internet Res · Dec 23, 2025 · Digital Health & AI, Cardiology

Wearing accelerometers 76 days on average linked to slight improvement in walk distance

Research · BMC Med · May 20, 2026 · Digital Health & AI, Oncology

Development and validation of an MRI-based deep learning system for triple-class ER expression classification in breast cancer: a large-scale multicenter study