ResearchJACC: Advances · Jun 13, 2026

Pressure-Adjusted Heart Rate by Echocardiography and Mortality in the Cardiac Intensive Care Unit

Lipps KM, Darlington AM, Dahiya G, Hillerson DB, Berg DD, Ternus BW, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Pressure-adjusted heart rate (HR) (PAHR) provides an integrated assessment of hemodynamic decompensation in critical illness. Objectives We aimed to evaluate the association of noninvasively obtained PAHR and mortality in cardiac intensive care unit (CICU) patients. Methods This was a retrospective cohort of patients with a transthoracic echocardiogram (TTE) within 24 hours of admission to an academic CICU (2007-2018). HR, right atrial pressure (RAP), and mean arterial pressure (MAP) obtained from the TTE were used to calculate PAHR as RAP · HR/MAP (in beats/min). The primary outcome was in-hospital mortality and secondary outcome was one-year mortality. Results Among 5,411 patients (median 70.1 years, 38.6% female, 92.4% White), higher PAHR was associated with greater acute illness severity, comorbidities, and critical care therapy utilization. The median PAHR was higher among patients who died while hospitalized (14.3 beats/min vs 6.8 BPM; P < 0.001). Echocardiographic measurements of biventricular function, filling pressures, and cardiac output were worse among those with higher PAHR. In-hospital mortality (adjusted OR: 1.03; 95% CI: 1.01 to 1.05; P = 0.001) and one-year (adjusted HR: 1.03; 95% CI: 1.02-1.04; P < 0.001) mortality increased with each 1 BPM higher PAHR. PAHR had moderate discrimination for in-hospital mortality (C-statistic 0.75). Conclusions PAHR is a readily determinable composite measure of cardiovascular status that enhances clinical risk stratification of critically ill patients, performing better than MAP, HR, and Modified Shock Index. Among CICU patients, higher PAHR by TTE was associated with greater mortality.

DOI: 10.1016/j.jacadv.2026.102887 · PubMed: 42287782

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Lipps KM, Darlington AM, Dahiya G, et al. Pressure-Adjusted Heart Rate by Echocardiography and Mortality in the Cardiac Intensive Care Unit. JACC Adv. 2026;5(7):102887. doi:10.1016/j.jacadv.2026.102887

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

More in Cardiology

Research · JACC Adv · Nov 26, 2026 · Cardiology

No significant rise in anti-gal IgE found after bioprosthetic aortic valve replacement

Research · JACC Adv · Nov 26, 2026 · Cardiology, Nephrology

Pecavaptan linked to lower kidney function and higher urine albumin in heart failure

Research · JACC Adv · Nov 26, 2026 · Cardiology

Expert panel proposes framework for interventional heart failure specialist training

Research · JACC Adv · Nov 26, 2026 · Cardiology, Psychiatry & Mental Health

Mental health burden linked to lower angina improvement in ANOCA patients

Research · JACC Adv · Nov 26, 2026 · Cardiology, Medical Genetics & Genomics

Rare genetic variants found in nearly 60% of Swedish SCAD patients