Injuries during initial entry for laparoscopic surgery are uncommon in patients with obesity
Primary entry trocar design and entry-related complications at laparoscopy in obese patients: meta-analysis
Clinical question: Does primary entry trocar design affect entry-related complications in obese patients?
Why it matters: It is unknown if the specific design of the primary entry trocar influences the rate of abdominal injuries in patients with a body mass index over 30 kg/m2.
- Researchers analyzed 5403 patients across 13 observational studies with a mean body mass index of 45.93 kg/m2.
- The overall incidence of vascular and visceral injuries during initial entry was 8.1 per 1000 events.
- Optical trocars, which allow surgeons to see through the device, showed one injury per 100 compared to four per 100 for non-optically enabled devices.
Limitation the authors note: The evidence was insufficient and largely of low quality due to considerable heterogeneity in the small number of examined studies.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Miti C, Busuulwa P, Scott R, Bloomfield-Gadelha H. Primary entry trocar design and entry-related complications at laparoscopy in obese patients: meta-analysis. BJS Open. 2023. doi:10.1093/bjsopen/zrad047