Prompt Configurations for Multimodal Large Language Models in Diagnosing and Staging Osteonecrosis of the Femoral Head: Multimodel Retrospective Observational Diagnostic Study

Zhu J, Huang X, Shi J, Chen S, Chen D, Gao Z, et al
Digital Health & AIAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Multimodal large language models (MLLMs) have emerging potential for interpreting medical images and text, but their performance in orthopedic imaging tasks and the influence of prompt configuration remain insufficiently studied. Objective This study aimed to evaluate the performance of commercial and open-source MLLMs for diagnosing and staging osteonecrosis of the femoral head (ONFH) and to assess how different prompt configurations affect model performance. Methods This single-center retrospective diagnostic accuracy study included 159 radiograph patients contributing 318 hip-level observations and 170 magnetic resonance imaging (MRI) patients contributing 340 hip-level observations; 55 patients with both modalities formed the multi-image (MI) subgroup between July 2023 and December 2024. Four MLLMs were evaluated: GPT-4o, Claude 3.7 Sonnet, Qwen2.5-VL 72B, and Gemma 3 27B. Three prompt configurations were tested: single image (SI), image plus radiology description (ID), and MI. Model performance was assessed for ONFH detection; early- versus late-stage differentiation; detailed grading using the Ficat, Association Research Circulation Osseous (ARCO), and Steinberg systems; and grading reliability using intraclass correlation coefficients (ICCs). Results Model performance varied by prompt configuration and imaging input. For ONFH detection, the SI configuration yielded a mean detection area under the receiver operating characteristic curve (AUC) of 0.55 (SD 0.03), whereas the ID configuration achieved a mean detection AUC of 0.91 (SD 0.01). In radiograph-based ONFH detection, ID input achieved a mean accuracy of 0.88 (SD 0.01); in MRI-based ONFH detection, ID input achieved a mean accuracy of 0.85 (SD 0.01). For early- versus late-stage differentiation, the mean accuracy was 0.65 (SD 0.11) with SI input, 0.78 (SD 0.04) with ID input, and approximately 0.59 (SD 0.10) with MI input. For detailed grading, ID input improved mean accuracy across the Ficat, ARCO, and Steinberg systems compared with SI input. In ARCO grading reliability analysis, the mean MLLM ICC was 0.51 (SD 0.18) for SI, 0.97 (SD 0.02) for ID, and 0.49 (SD 0.15) for MI; surgeon interrater and intrarater ICCs were 0.70 and 0.81, respectively. In the commercial versus open-source model comparison, no significant overall difference was observed between model groups (P=.83). Conclusions Prompt configuration strongly influenced MLLM performance in ONFH diagnosis and staging. Pairing images with deidentified radiology descriptions improved diagnostic and grading performance, whereas MI input did not provide consistent additional benefit in this retrospective single-center evaluation. These findings support the potential role of MLLMs as assistive tools in human-AI orthopedic imaging workflows, but external validation, careful input standardization, and prospective clinical evaluation are needed before clinical deployment.

Topics

Humans; Retrospective Studies; Large Language Models; Magnetic Resonance Imaging; Femur Head Necrosis; Female; Male

DOI: 10.2196/92919 · PubMed: 42573734

Spotted a mistake? Suggest a correction

More in Digital Health & AI

ResearchLancet Digit Health · Nov 23, 2026 · Digital Health & AI

ClinicalAge biomarker associated with mortality and disease risk in UK datasets

ClinicalAge, a framework for modelling ageing trajectories from longitudinal electronic health records in the UK: a model development and validation study

ResearchLancet Digit Health · Nov 23, 2026 · Digital Health & AI

Facial photographs used to estimate age and predict survival in cancer patients

Foundation artificial intelligence models for health recognition by use of face photographs (FAHR-Face): a model development and validation study

ResearchLancet Digit Health · Nov 23, 2026 · Digital Health & AI

New model predicts severe fetal compromise risk at birth with 33.4% sensitivity

A prognostic model for use at labour onset to estimate the risk of severe fetal compromise at birth: a retrospective, model development and validation study

ResearchNPJ Digit Med · Nov 21, 2026 · Digital Health & AI

ECG foundation models performed well on general data but less so on athletes' data

ECG foundation models for cardiovascular screening in a cohort of young competitive athletes

ResearchJ Med Internet Res · Nov 20, 2026 · Digital Health & AI

Six large language models showed similar question-answering accuracy on medical exam questions

Medical Reasoning in Large Language Models: Development and Evaluation of the MedEvalArena Benchmark