Visual abstractsVisuals
ResearchOphthalmology Science · Apr 15, 2026

Prospective Data Curation Enables High-Performance Artificial Intelligence for Diabetic Retinopathy Screening in a Resource-Limited Setting

Ashrafzadeh CM, Bahi M, Mostafa A, El Manhaly M, Ghoneim M, Al-Bayoumy B, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose To determine whether a high-quality, prospectively curated dataset can, by itself, enable the development of robust and clinically effective artificial intelligence as a medical device (AIaMD) models for diabetic retinopathy (DR) screening, even with minimal artificial intelligence (AI) infrastructure. This study evaluates whether careful data curation, standardized acquisition, and rigorous grading processes can yield high-performing AI models for more-than-mild DR (MTM) and diabetic macular edema (DME) detection from ultra-widefield (UWF) fundus images. Design An evaluation of diagnostic technology. Subjects Patients with diabetes receiving imaging at Alexandria iCare Retina Reading Center. Methods A total of 152 025 UWF color images were collected between February 2022 and June 2024 at a UWF image reading center during routine screening. This was a cross-sectional study with patient consent obtained at the time of imaging. After excluding noncolor or ungradable images, 26 232 UWF color images from 5394 diabetic patients were used to train 2 Inception V3-based convolutional neural networks: one to detect MTM and another for OCT-confirmed DME. Images were split 80:10:10 by patient into training, validation, and test sets. Models were trained on red-green channel inputs using standard augmentation and Adam optimization (learning rate 0.0005). Prospective validation was performed on 12 698 additional images from 3096 patients collected between July and December 2024, following identical imaging and adjudication protocols. Main outcome measures Area under the curve (AUC), sensitivity, and specificity. Results In baseline testing, the MTM model achieved an AUC of 0.962 ± 0.003, sensitivity of 0.922 ± 0.001, and specificity of 0.873 ± 0.010; the DME model achieved an AUC of 0.879 ± 0.014, sensitivity of 0.809 ± 0.022, and specificity of 0.790 ± 0.023. In the prospective dataset, the MTM model maintained strong performance (AUC 0.949; sensitivity 0.86-0.89; specificity 0.85-0.89), while the DME model yielded an AUC of 0.821 with balanced sensitivity (0.76) and specificity (0.73). Gradient-weighted class activation mapping visualizations confirmed focus on clinically relevant lesions. Conclusions This study demonstrates that rigorous prospective data collection and quality control can produce high-performing AIaMDs even with limited AI engineering resources. Locally curated datasets aligned with regional populations, equipment, and workflows can yield reliable, regulation-ready tools that advance equitable DR screening in resource-limited settings. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101191 · PubMed: 42222586

Spotted a mistake? Suggest a correction

More in Ophthalmology

ResearchPediatricAm J Ophthalmol · Nov 20, 2026 · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

Association of allergic conjunctivitis severity with meibomian gland abnormalities in children: a cross-sectional study

Randomized trialVisual abstractPediatricJAMA Ophthalmol · Nov 19, 2026 · Ophthalmology

Higher concentration atropine drops slowed myopia progression in children

Low-Concentration Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT2 Randomized Clinical Trial

ResearchAm J Ophthalmol · Nov 19, 2026 · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Smoke, Not Smoking, as a Possible Risk Factor Triggering Conversion in Leber's Hereditary Optic Neuropathy: A Retrospective Case Series

ResearchOphthalmology · Nov 18, 2026 · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Trends and Variation in Uveal Melanoma Management in the National Cancer Database, 2004-2023

ResearchAm J Ophthalmol · Nov 18, 2026 · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients

Developing Static Perimetry Thresholds to Assess Visual Field Loss Severity in Patients with Retinitis Pigmentosa