Coil embolisation during stent graft repair was associated with fewer endoleaks in abdominal aortic aneurysm patients
Prospective, Randomised Two Centre Trial of Endovascular Repair of Abdominal Aortic Aneurysm With or Without Sac Embolisation
Key points
- Ninety-four patients at high risk for type II endoleak, a blood leak into the aneurysm sac, were randomised to standard endovascular repair or repair with coil embolisation.
- At 6 months, type II endoleaks occurred in 41.7% of the standard repair group compared to 4.26% in the coil embolisation group.
- The coil embolisation group showed significantly faster aneurysm sac volume shrinkage at 12 months and 24 months compared to the standard repair group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Fabre D, Mougin J, Mitilian D, et al. Prospective, Randomised Two Centre Trial of Endovascular Repair of Abdominal Aortic Aneurysm With or Without Sac Embolisation. Eur J Vasc Endovasc Surg. 2021;61(2):201-209. doi:10.1016/j.ejvs.2020.11.028
Spotted a mistake? Suggest a correction