Visual abstractsVisuals
Clinical trialNew England Journal of Medicine · Apr 29, 2026

Pulmonary Tuberculosis Detection with MiniDock MTB Using Swab Samples

Yerlikaya S, Chirwa M, Ajide B, Castro MDM, Ha H, Kato-Maeda M, et al
Infectious DiseaseAdult and pediatric
Read the full paper free at PubMed Central ↗

Abstract

Background Improved diagnostic tools for tuberculosis that are suitable for use in peripheral health centers are essential for reducing the persistent gap between estimated and notified cases. The diagnostic accuracy and usability of the MiniDock MTB test for detecting pulmonary tuberculosis is unknown. Methods We conducted a prospective, cross-sectional study at outpatient centers in India, Nigeria, the Philippines, South Africa, Uganda, Vietnam, and Zambia. Patients 12 years of age or older with presumptive pulmonary tuberculosis were enrolled between September 12, 2024, and March 31, 2025. Assessment with MiniDock MTB was performed with sputum swabs and tongue swabs. Diagnostic accuracy was evaluated against a sputum-culture-based reference and as compared with sputum-smear microscopy and Xpert MTB/RIF Ultra assay. Usability was assessed with a system usability scale and direct observation. Results A total of 1380 participants were enrolled; 255 (18.5%) had human immunodeficiency virus infection and 226 (16.4%) had culture-confirmed tuberculosis. MiniDock MTB sensitivity was 85.7% (95% confidence interval [CI], 80.4 to 90.0) with sputum and 79.6% (95% CI, 73.8 to 84.7) with tongue swabs; specificity was greater than 97.5% for both. Results of sputum tests with MiniDock MTB closely matched those with Xpert MTB/RIF Ultra for sensitivity (difference, -2.8 percentage points; 95% CI, -6.0 to 0.5). MiniDock MTB had greater sensitivity than smear microscopy for tests of sputum (difference, 24.3 percentage points; 95% CI, 17.9 to 30.7) and tongue swabs (difference, 18.3 percentage points; 95% CI, 12.0 to 24.7). The test showed diagnostic accuracy that was consistent with World Health Organization (WHO) accuracy targets for near-point-of-care tuberculosis diagnostics (≥85% sensitivity for sputum and ≥75% for nonsputum and ≥98% specificity for both). The median score on the system usability scale (range, 0 to 100, with higher scores indicating better perceived usability) was 75 (interquartile range, 65 to 80), which indicated good usability. No adverse events related to the index test were reported. Conclusions MiniDock MTB met WHO targets for diagnostic accuracy and usability for tuberculosis detection across diverse clinical settings. (Funded by the National Institutes of Health and others; Rapid Research in Diagnostics Development for TB Network and Assessing Diagnostics at Point-of-Care for Tuberculosis ClinicalTrials.gov numbers, NCT04923958 and NCT05941052.).

Topics

Adolescent; Adult; Aged; Child; Female; Humans; Male; Middle Aged; Young Adult; Cross-Sectional Studies; HIV Infections; Mycobacterium tuberculosis

DOI: 10.1056/NEJMoa2509761 · PubMed: 42054680 · Registered: NCT04923958, NCT05941052

Spotted a mistake? Suggest a correction

More in Infectious Disease

ResearchClin Microbiol Infect · Nov 21, 2026 · Infectious Disease

Only ENDOVAL score met threshold for predicting in-hospital mortality in infective endocarditis

External validation of mortality risk scores in infective endocarditis: one size does not fit all

ReviewClin Microbiol Infect · Nov 21, 2026 · Infectious Disease

Rapid susceptibility testing methods shorten time to results for new antibiotics

Which rapid susceptibility testing methods for new antibiotics in clinical practice? a narrative review

ResearchClin Infect Dis · Nov 20, 2026 · Infectious Disease

Survey defines clinical work standards in academic infectious diseases

A Survey of Clinical Full-Time Equivalents in Academic Infectious Diseases

ResearchEuro Surveill · Nov 20, 2026 · Infectious Disease

Leptospirosis hospitalisation rate decreased in Guadeloupe between 2005 and 2023

Incidence and case fatality of patients hospitalised with leptospirosis, overseas departments, France, 2005 to 2023

ResearchEuro Surveill · Nov 20, 2026 · Infectious Disease

Forty-nine dengue cases reported in Italy after holiday site exposure

Autochthonous dengue outbreak spreading from a holiday site to visitors' places of residence, Tuscany, Italy, August to October 2026