Visual abstractsVisuals
ResearchBritish Journal of Ophthalmology · Sep 23, 2026

Quantitative framework for synthesising defocus-curve evidence in simultaneous-vision intraocular lenses

Passaro ML, Giuliano F, Buzzi M, Ventura M, Mencucci R, Lucenteforte E, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background/aims To develop a quantitative, meta-analytic framework to synthesise defocus-curve evidence and describe functional visual performance of simultaneous vision intraocular lenses (SVIOLs) across clinically relevant visual ranges. Methods PubMed was searched from inception through June 2025 using predefined terms related to cataract surgery, intraocular lenses and defocus curves. Studies of cataract surgery or refractive lens exchange with capsular bag implantation of SVIOLs reporting postoperative defocus curves were included. Randomised and non-randomised studies, cohort studies and case series were eligible. Defocus-curve data were extracted from tables or digitised from figures and summarised within predefined ranges: far (+1.00 to -0.50 D), intermediate (-0.50 to -2.00 D) and near (-2.00 to -3.50 D). Random-effects meta-analyses were performed for each IOL model. Exploratory latent class analysis (LCA) and meta-regression assessed performance patterns and associations with patient-reported outcomes. Outcomes included mean logMAR visual acuity across visual ranges, data-driven clustering of IOL performance and association with spectacle independence. Results A total of 125 studies including 18 077 eyes and 84 IOL models were analysed. Across IOL models, 97.1% achieved mean far acuity of 0.2 logMAR or better compared with 71.6% for intermediate and 67.5% for near. Considerable between-study heterogeneity was observed across all ranges. LCA identified four clusters reflecting a continuum from full-range to distance-dominant visual performance. Better near visual acuity was significantly associated with higher spectacle independence, explaining 45.2% of its variance. Conclusions Range-based descriptors enable reproducible comparison across heterogeneous studies and support evidence synthesis. This framework provides a practical approach to operationalise functional classification of SVIOLs and link visual performance to patient-reported outcomes.

Abstract reproduced under the article’s CC BY NC licence.

DOI: 10.1136/bjo-2026-329959 · PubMed: 42778340

Spotted a mistake? Suggest a correction

More in Ophthalmology

ResearchPediatricAm J Ophthalmol · Nov 20, 2026 · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

Association of allergic conjunctivitis severity with meibomian gland abnormalities in children: a cross-sectional study

Randomized trialVisual abstractPediatricJAMA Ophthalmol · Nov 19, 2026 · Ophthalmology

Higher concentration atropine drops slowed myopia progression in children

Low-Concentration Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT2 Randomized Clinical Trial

ResearchAm J Ophthalmol · Nov 19, 2026 · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Smoke, Not Smoking, as a Possible Risk Factor Triggering Conversion in Leber's Hereditary Optic Neuropathy: A Retrospective Case Series

ResearchOphthalmology · Nov 18, 2026 · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Trends and Variation in Uveal Melanoma Management in the National Cancer Database, 2004-2023

ResearchAm J Ophthalmol · Nov 18, 2026 · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients

Developing Static Perimetry Thresholds to Assess Visual Field Loss Severity in Patients with Retinitis Pigmentosa