Visual abstractsVisuals
Randomized trialEuropean Radiology · Jul 16, 2024

Radiation exposure and screening yield by digital breast tomosynthesis compared to mammography: results of the TOSYMA Trial breast density related

Sommer A, Weigel S, Hense HW, Gerß J, Weyer-Elberich V, Kerschke L, et al
Radiology & ImagingOncologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives The randomized TOmosynthesis plus SYnthesized MAmmography (TOSYMA) screening trial has shown that digital breast tomosynthesis plus synthesized mammography (DBT + SM) is superior to digital mammography (DM) in invasive breast cancer detection varying with breast density. On the other hand, the overall average glandular dose (AGD) of DBT is higher than that of DM. Comparing the DBT + SM and DM trial arm, we analyzed here the mean AGD and their determinants per breast density category and related them to the respective invasive cancer detection rates (iCDR). Methods TOSYMA screened 99,689 women aged 50 to 69 years. Compression force, resulting breast thickness, the calculated AGD obtained from each mammography device, and previously published iCDR were used for comparisons across breast density categories in the two trial arms. Results There were 196,622 exposures of 49,227 women (DBT + SM) and 197,037 exposures of 49,132 women (DM) available for analyses. Mean breast thicknesses declined from breast density category A (fatty) to D (extremely dense) in both trial arms. However, while the mean AGD in the DBT + SM arm declined concomitantly from category A (2.41 mGy) to D (1.89 mGy), it remained almost unchanged in the DM arm (1.46 and 1.51 mGy, respectively). In relative terms, the AGD elevation in the DBT + SM arm (64.4% (A), by 44.5% (B), 27.8% (C), and 26.0% (D)) was lowest in dense breasts where, however, the highest iCDR were observed. Conclusion Women with dense breasts may specifically benefit from DBT + SM screening as high cancer detection is achieved with only moderate AGD elevations. Clinical relevance statement TOSYMA suggests a favorable constellation for screening with digital breast tomosynthesis plus synthesized mammography (DBT + SM) in dense breasts when weighing average glandular dose elevation against raised invasive breast cancer detection rates. There is potential for density-, i.e., risk-adapted population-wide breast cancer screening with DBT + SM. Key points Breast thickness declines with visually increasing density in digital mammography (DM) and digital breast tomosynthesis (DBT). Average glandular doses of DBT decrease with increasing density; digital mammography shows lower and more constant values. With the smallest average glandular dose difference in dense breasts, DBT plus SM had the highest difference in invasive breast cancer detection rates.

Topics

Humans; Female; Mammography; Middle Aged; Breast Neoplasms; Aged; Breast Density; Radiation Exposure; Early Detection of Cancer; Radiation Dosage; Breast; Mass Screening

DOI: 10.1007/s00330-024-10847-9 · PubMed: 39012526

Cite this article

Sommer A, Weigel S, Hense HW, Gerß J, Weyer-Elberich V, Kerschke L. Radiation exposure and screening yield by digital breast tomosynthesis compared to mammography: results of the TOSYMA Trial breast density related. Eur Radiol. 2024. doi:10.1007/s00330-024-10847-9

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

JNCI Cancer Spectr · Oct 11, 2024 · Meta-analysis · Oncology, Radiology & Imaging

Clinical guidelines for the management of mammographic density: a systematic review of breast screening guidelines worldwide

Eur Radiol · Jun 10, 2026 · Research · Radiology & Imaging, Digital Health & AI

Comparison of three algorithms to measure breast density on mammograms in a population-based screening cohort

BMJ · Dec 3, 2025 · Randomized trial · Oncology, Public & Global Health Visual abstract

Notifying women of dense breast tissue was associated with increased anxiety and confusion

Ann Intern Med · Mar 3, 2026 · Research · Oncology, Radiology & Imaging

Outcomes of Density-Targeted Supplemental Breast Magnetic Resonance Imaging Screening by Breast Cancer Risk: Long-Term Health and Economic Considerations

Eur Radiol · May 6, 2026 · Research · Radiology & Imaging, Oncology

A comparison of tumour characteristics of screen-detected and interval cancers and their relationship with breast density and AJCC prognostic stage in a UK screening cohort