Radiopaque tissue transfer system did not reduce positive margin rates in breast-conserving surgery
Radiopaque tissue transfer and X-ray system versus standard specimen radiography for intraoperative margin assessment in breast-conserving surgery: randomized clinical trial
Clinical question: Does radiopaque tissue transfer and X-ray system reduce positive margin rate in breast-conserving surgery?
Why it matters: The efficacy of using devices to precisely localize affected margins during specimen radiography to reduce positive margin rates in breast-conserving surgery is unclear.
- Researchers randomized 117 patients with microcalcification-associated breast cancer to receive either a radiopaque tissue transfer and X-ray system or the institutional standard specimen radiography.
- The positive margin rate was 31.7% for the radiopaque tissue transfer group and 26.3% for the standard group, which was not a statistically significant difference.
- Tumor size greater than 30 mm and specimen size greater than 50 mm were independent factors associated with positive margins.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Topics
Cite this article
Stachs A, Bollmann J, Martin A, Stubert J, Reimer T, Gerber B. Radiopaque tissue transfer and X-ray system versus standard specimen radiography for intraoperative margin assessment in breast-conserving surgery: randomized clinical trial. BJS Open. 2022. doi:10.1093/bjsopen/zrac091
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.