Guide sheath use in lung biopsy showed higher cytology yield but similar pathology results
Randomised trial of assessing diagnostic yield in transbronchial biopsy with a guide sheath
Clinical question: Does a guide sheath increase diagnostic yield in radial probe endobronchial ultrasound guided transbronchial biopsy?
Why it matters: It is unknown whether using a guide sheath during radial probe endobronchial ultrasound-guided transbronchial biopsy increases the diagnostic yield for peripheral lung lesions.
- Researchers studied 102 patients with peripheral lung lesions assigned to either radial probe endobronchial ultrasound-guided biopsy with a guide sheath or the conventional method without a sheath.
- The pathology yield was 75.9% in the guide sheath group versus 68.8% in the conventional group, which was not a statistically significant difference.
- The guide sheath group had higher brushing cytology yields of 64.3% versus 42.9% and lower bleeding rates of 9.3% versus 20.8%.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Cite this article
Chang HC, Kuo YW, Lin CK, Chang LC, Chen YY, Yang CY. Randomised trial of assessing diagnostic yield in transbronchial biopsy with a guide sheath. ERJ Open Res. 2025. doi:10.1183/23120541.00771-2024