Vacuum clot removal was associated with greater reduction in heart strain than anticoagulation alone
Randomized Controlled Trial of Mechanical Thrombectomy With Anticoagulation Versus Anticoagulation Alone for Acute Intermediate-High Risk Pulmonary Embolism: Primary Outcomes From the STORM-PE Trial
Clinical question: Is mechanical thrombectomy plus anticoagulation better than anticoagulation alone for intermediate-high risk pulmonary embolism?
Why it matters: It is unclear if computer-assisted vacuum thrombectomy is more effective or safer than anticoagulation alone for patients with intermediate-high risk pulmonary embolism.
- The STORM-PE trial studied 100 adults with intermediate-high risk pulmonary embolism randomized to computer-assisted vacuum thrombectomy with anticoagulation or anticoagulation alone.
- At 48 hours, the mean reduction in the right ventricular to left ventricular diameter ratio was 0.52±0.37 for vacuum thrombectomy versus 0.24±0.40 for anticoagulation alone.
- The rate of major adverse events within 7 days was 4.3% for the vacuum thrombectomy group and 7.5% for the anticoagulation group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Topics
Cite this article
Lookstein RA, Konstantinides SV, Weinberg I, Dohad SY, Rosol Z, Kopeć G. Randomized Controlled Trial of Mechanical Thrombectomy With Anticoagulation Versus Anticoagulation Alone for Acute Intermediate-High Risk Pulmonary Embolism: Primary Outcomes From the STORM-PE Trial. Circulation. 2025. doi:10.1161/CIRCULATIONAHA.125.077232
Spotted a mistake? Suggest a correction