Rapid molecular assays show lower sensitivity than blood cultures for detecting bloodstream infections
Rapid molecular assays versus blood culture for bloodstream infections: a systematic review and meta-analysis
Clinical question: What is the diagnostic performance of rapid molecular assays compared to blood culture for bloodstream infections?
Why it matters: The diagnostic accuracy of various commercial rapid molecular assays for detecting bloodstream infections has not been comprehensively reviewed.
- Researchers analyzed 75 studies involving 17,952 samples and 11,393 patients to compare rapid molecular assays with traditional blood cultures.
- The pooled specificity of rapid molecular assays was 0.858, while the pooled sensitivity was 0.659 when analyzed by patient.
- Sensitivity for specific tests ranged from 0.492 for the MagicPlex Sepsis Test to 0.783 for the IRIDICA BAC BSI assay.
Limitation the authors note: The risk of bias was judged to be high in all included articles.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Rapszky GA, Do To UN, Kiss VE, et al. Rapid molecular assays versus blood culture for bloodstream infections: a systematic review and meta-analysis. EClinicalMedicine. 2025;79:103028. doi:10.1016/j.eclinm.2024.103028
Spotted a mistake? Suggest a correction