Visual abstractsVisuals
ResearchCirculation · Sep 22, 2026

Real-World Experience With the Extravascular Implantable Cardioverter Defibrillator Through 1 Year: The Enlighten Post Approval Registry Study

Boersma LVA, Amin A, Murgatroyd F, Sterliński M, Johansen JB, Saleh K, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background The extravascular implantable cardioverter defibrillator (EV-ICD) was developed to provide defibrillation and antitachycardia pacing therapy without the need for intravascular lead placement. Premarket clinical trials reported EV-ICD safety and efficacy through 3 years, but a real-world assessment of the Aurora EV-ICD system, which includes a novel sensing discriminator, is needed. The objective of this analysis was to assess real-world therapy efficacy and safety of the EV-ICD through 1 year. Methods Enlighten: The EV-ICD Post Approval Registry is a prospective, global, real-world registry that included patients who underwent an EV-ICD implantation attempt. The main safety analysis was freedom from all system- or procedure-related major complications through 1 year. Event rates at 1 year were calculated using the Kaplan-Meier method. Results EV-ICD system implantation was attempted by 168 implanters in 787 patients (49.1±15.2 years old; 28.7% women; 34.1% secondary prevention). Tunneling and lead placement in the substernal space were achieved in 781 of 787 patients (99.2%), with 758 patients (96.3%) remaining implanted following defibrillation and electrical testing. One-year freedom from major system- or procedure-related complications was 89.1% (95% CI, 86.3%-91.3%). The 1-year rate of first appropriate therapy (shock, antitachycardia pacing, or both) was 7.3% (95% CI, 5.5-9.6). Shock success for discrete spontaneous episodes was 100% (61 of 61), and the generalized estimating equations antitachycardia pacing success rate, to account for multiple episodes per patient, was 74.2% for monomorphic ventricular tachycardia. The 1-year rate of first inappropriate shock was 7.1% (95% CI, 5.4-9.4), with noncardiac oversensing as the main cause (40.5% of inappropriately shocked episodes). Conclusions In the largest prospective worldwide cohort of patients with an EV-ICD to date, both antitachycardia pacing and shock therapy were effective, while the rate of major complications agreed with the premarket experience through 1 year. These data demonstrate that positive outcomes of the EV-ICD are retained in everyday clinical practice in a large, global cohort with an expanded number of implanters. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT06048731.

Topics

Adult; Aged; Female; Humans; Male; Middle Aged; Defibrillators, Implantable; Electric Countershock; Product Surveillance, Postmarketing; Prospective Studies; Registries; Time Factors

DOI: 10.1161/CIRCULATIONAHA.126.080942 · PubMed: 42770223 · Registered: NCT06048731

Spotted a mistake? Suggest a correction

More in Cardiology

JACC Adv · Nov 23, 2026 · Research · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

JACC Adv · Nov 20, 2026 · Meta-analysis · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

JACC Adv · Nov 20, 2026 · Research · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Lancet · Nov 19, 2026 · Review · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

JACC · Nov 19, 2026 · Review · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk