Visual abstractsVisuals
ResearchJournal of the American Heart Association · Sep 18, 2026

Real-World External Validation of Artificial Intelligence-Based Full-Vessel Segmentation for Intracoronary Optical Coherence Tomography

Volleberg RHJA, Shin D, van der Waerden RGA, Porter CR, Thomas SV, Sosa F, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Artificial intelligence (AI) allows automated evaluation of intracoronary optical coherence tomography (OCT) images. However, algorithms are mostly developed and validated on well-curated data sets, which may not represent real-world data. We sought to externally validate a previously developed algorithm performing full-vessel segmentation for OCT in an unselected consecutive real-world data set. Methods This was a retrospective, single-center, external validation study comprising 100 consecutive patients undergoing clinically indicated OCT. A previously developed AI algorithm (OCT-AID) was used for automated pixelwise labeling of OCT images, distinguishing among lumen, guidewire artifact, intima, media, lipid plaque, calcium plaque, side branch, plaque rupture, thrombus, microvessel, and background. The AI-based predictions were compared on a frame level to the reference standard obtained through manual OCT image analysis by expert readers. Results Among 2560 analyzable frames, the agreement between the automated OCT image analysis and the reference standard was excellent for calcified plaque identification (κ=0.88 [95% CI, 0.84-0.92]) and quantification (intraclass correlation coefficient values ranged between 0.79 and 0.93), with a performance close to interobserver variability. For lipid plaque identification and quantification, the model performance was reasonable (κ=0.68 [95% CI, 0.64-0.72]; intraclass correlation coefficient for lipid arc, 0.79 [95% CI, 0.76-0.81]; intraclass correlation coefficient for minimum fibrous cap thickness, 0.59 [95% CI, 0.55-0.63]) and largely superior to interobserver variability. The algorithm performance for low-prevalence features (e.g., plaque rupture) was limited. Conclusions AI-based fully automated evaluation of OCT images is feasible with performances consistent with interobserver variability in a real-world data set of consecutive patients, supporting generalizability of the proposed methodology.

Topics

Tomography, Optical Coherence; Humans; Retrospective Studies; Artificial Intelligence; Coronary Vessels; Reproducibility of Results; Plaque, Atherosclerotic; Algorithms; Female; Male; Coronary Artery Disease; Image Interpretation, Computer-Assisted

DOI: 10.1161/JAHA.125.049353 · PubMed: 42757960

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology