Visual abstractsVisuals
ResearchERJ Open Research · Dec 29, 2025

Reversibility in plethysmographic airway and specific airway resistance in children

Beydon N, Du Boisbaudry C, Delclaux C, Abou Taam R, Ioan I, Matecki S, et al
PulmonologyPediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Plethysmographic airway resistance (R aw) and specific airway resistance (sR aw) are widely used to assess baseline lung function and bronchodilator reversibility in children unable to perform spirometry. However, no consensus exists on cut-offs for significant reversibility. Methods We conducted a retrospective study on a large cohort of asthmatic children tested during panting without electronic thermal compensation, to determine optimal R aw and sR aw cut-offs for detecting significant forced expiratory volume in 1 s (FEV1) reversibility. A smaller cohort undergoing tidal breathing plethysmography with electronic thermal compensation was also analysed. Results From 2436 tests without thermal compensation, receiver operating characteristic curve analysis identified cut-offs of -34.4% (R awtot) and -36.0% (sR awtot) from baseline to detect significant FEV1 reversibility, with sensitivities of 70% (95% CI 65-74%) and 72% (95% CI 67-76%) and specificities of 70% (95% CI 68-72%) and 73% (95% CI 71-75%), respectively. Expressing reversibility as a percentage of predicted did not improve accuracy, but required larger cut-offs (-42.6% for R awtot, -56.1% for sR awtot) and increased the influence of baseline value. In the 106 tests performed using electronic thermal compensation, R awtot/eff and sR awtot/eff cut-offs were lower than that without electronic thermal compensation (-25% of baseline) with sensitivities and specificities ranging from 63% to 70%. Conclusion R awtot and sR awtot reversibility effectively identify FEV1 reversibility with cut-offs around -35% of the baseline value, showing no added benefit when using larger cut-offs expressed as a percentage of the predicted value. When electronic thermal compensation is applied, it may necessitate lower cut-offs of -25% of the baseline, compared to those determined without it.

DOI: 10.1183/23120541.00727-2025 · PubMed: 41473548

Cite this article

Beydon N, Du Boisbaudry C, Delclaux C, Abou Taam R, Ioan I, Matecki S. Reversibility in plethysmographic airway and specific airway resistance in children. ERJ Open Res. 2025. doi:10.1183/23120541.00727-2025

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Pulmonology

Eur Respir J · Nov 23, 2026 · Review · Pulmonology, Cardiology

BMP-9 and BMP-10 regulate pulmonary vascular resilience through complex pathways

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Needle aspiration reduced hospital stay by nearly five days for pneumothorax patients

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology, Allergy & Immunology Visual abstract

Inhaled itraconazole improved lung function and asthma control at 40mg dose

Ann Fam Med · Nov 23, 2026 · Research · Family Medicine & Primary Care, Infectious Disease

Respiratory virus immunization guidance issued for 2026-2027 season

Ann Fam Med · Nov 23, 2026 · Research · Family Medicine & Primary Care, Infectious Disease

Antibiotic prescribing for respiratory tract diagnoses decreased with intervention