Visual abstractsVisuals
Meta-analysisAmerican Journal of Ophthalmology · Dec 2, 2025

Risk Factors for Failure in Minimally Invasive Bleb Surgery: A Systematic Review

Jung M, Kong YZ, Ansari AS, Lawlor M, Tan JCK
OphthalmologyAdult
Read the full paper free at the publisher ↗

Abstract

Purpose Minimally invasive bleb surgery (MIBS) reduces intraocular pressure (IOP) and IOP-lowering medication use, with a safer adverse effect profile compared to traditional filtration surgery. This review examined risk factors for surgical failure following MIBS. Design Systematic review. Methods A systematic review (Prospero ID: CRD42024572750) of Embase, Web of Science, and MEDLINE identified studies which reported ophthalmic or demographic factors significantly associated with surgical failure following MIBS. Risk of bias was evaluated using Quality in Prognostic Studies (QUIPS), evidence quality using Centre for Evidence-Based Medicine (CEBM), and certainty of evidence using Grading of Recommendations, Assessment, Development and Evaluation (GRADE). Results Of 394 articles identified, 18 studies comprising 19 cohorts (9580 eyes of 9281 subjects) were included. Twelve cohorts evaluated the XEN Gel Stent and 7 examined the PreserFlo MicroShunt. Non-White ethnicity (Asian and non-Hispanic Black) and lower intraoperative dosing/omission of intra-operative Mitomycin-C was associated with higher risk of failure; both associations had low certainty of evidence. Associations between glaucoma diagnosis and surgical failure were conflicting, with very low certainty of evidence; several studies described higher risk of failure for pseudoexfoliative/pigmentary, angle closure, uveitic, and normal tension subtypes of glaucoma. Conversely, lower risk of failure was reported among ocular hypertension/open-angle suspects. Most studies had low risk of bias and evidence quality was low to moderate. Conclusion This review identified demographic and preoperative factors associated with MIBS failure, especially non-White ethnicity and reduced/no MMC use. These findings may guide patient selection and future studies; however, the low certainty of evidence warrants cautious interpretation.

Topics

Humans; Risk Factors; Minimally Invasive Surgical Procedures; Intraocular Pressure; Glaucoma; Treatment Failure; Filtering Surgery; Trabeculectomy; Postoperative Complications

DOI: 10.1016/j.ajo.2025.11.045 · PubMed: 41344530 · Registered: PROSPERO CRD42024572750

Cite this article

Jung M, Kong YZ, Ansari AS, Lawlor M, Tan JCK. Risk Factors for Failure in Minimally Invasive Bleb Surgery: A Systematic Review. Am J Ophthalmol. 2025. doi:10.1016/j.ajo.2025.11.045

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Am J Ophthalmol · Sep 12, 2026 · Research · Ophthalmology

Long-Term Visual Field Outcomes After Failed Trabeculectomy: Same-Site Trabeculectomy Versus Ahmed Glaucoma Valve Implantation

Br J Ophthalmol · Aug 20, 2026 · Research · Ophthalmology

Aqueous humour outflow improvement after excimer laser trabeculostomy

Invest Ophthalmol Vis Sci · Oct 22, 2026 · Research · Basic science · Ophthalmology

USP10 Silencing Prevents Scarring and Inflammation in a Modified Rabbit Model of Glaucoma Filtration Surgery

Br J Ophthalmol · Jun 22, 2026 · Review · Pediatric · Ophthalmology

Trabeculotomy outcomes in paediatric patients with steroid-induced ocular hypertension or glaucoma: a case series and literature review

Invest Ophthalmol Vis Sci · Jan 13, 2026 · Research · Basic science · Ophthalmology

Effects of Micropulse Laser Trabeculoplasty on Intraocular Pressure and Aqueous Humor Outflow in Pigmented Rabbits