Risk-Guided Atrial Fibrillation Screening With Artificial Intelligence-Enabled Electrocardiogram Models: A VITAL-AF Trial Analysis
Abstract
Background
Screening for atrial fibrillation (AF) may lead to earlier detection and initiation of preventive measures. Current AF screening approaches using a guideline age-based threshold of ≥65 years have shown limited yield. Objectives
In an AF screening trial, we assessed whether the screening effect was larger among individuals at elevated AF risk using validated clinical and electrocardiogram (ECG)-based artificial intelligence (AI) risk models. Methods
VITAL-AF was a cluster-randomized trial of patients aged ≥65 years treated at 1 of 16 primary care practices affiliated with Massachusetts General Hospital. Patients randomized to a screening practice were screened using a single-lead ECG. Among VITAL-AF participants without prevalent AF with at least one 12-lead ECG within 3 years before enrollment, we estimated AF risk using 3 validated models derived outside of VITAL-AF: the Cohorts of Heart and Aging Research in Genomic Epidemiology-AF (CHARGE-AF) clinical score, an AI-based model using a 12-lead ECG alone (ECG-AI), and a model combining ECG-AI and CHARGE-AF (CH-AI). Two-year incident AF discrimination was assessed by the time-dependent area under the receiver-operating characteristic curve (AUROC) and average precision. AF screening effect was defined as the difference in 2-year incident AF diagnosis rate (per 100 person-years) in screening vs control across AF risk deciles. Results
Of 30,630 VITAL-AF participants without prevalent AF, 16,937 had pretrial ECG and clinical data. Each score discriminated 2-year AF risk according to AUROC (CHARGE-AF: 0.711 [95% CI: 0.671-0.749]; ECG-AI: 0.784 [95% CI: 0.743-0.819]; CH-AI: 0.788 [95% CI: 0.754-0.824]) and average precision (0.0952 [95% CI: 0.0836-0.112]; 0.132 [95% CI: 0.113-0.157]; 0.133 [95% CI: 0.117-0.159]). An AF screening effect was observed in the top decile of CH-AI (AF diagnosis rate in screening 10.07/100 person-years [95% 8.28-11.87] vs 7.76 [95% 6.30-9.21] in control, P Conclusions
Use of ECG-based AI and clinical factors identified individuals at particularly high risk for AF who may benefit from screening. Findings suggest a trade-off between increasing AF screening efficiency and decreasing population coverage (ie, restriction of the screening pool). Future studies are needed to determine whether a risk-based approach is optimal or whether consideration of additional clinical- and systems-level factors (eg, access, health care system engagement) can further refine AF screening strategies. (Screening for Atrial Fibrillation Among Older Patients in Primary Care Clinics [VITAL-AF]; NCT03515057).
Topics
Spotted a mistake? Suggest a correction
More in Cardiology
Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations
Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis
Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately
Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms
Spontaneous coronary artery dissection affects younger women more often than expected
Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research
Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk
Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology