Visual abstractsVisuals
ResearchOphthalmology Science · Feb 6, 2026

Simultaneous Segmentation of Geographic Atrophy in Longitudinally Acquired Fundus Autofluorescence Images

Mukherjee S, Chew E, Keenan TDL, Lu Z, Sherif N, Arunachalam T, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose Accurately measuring geographic atrophy (GA) progression in clinical trials is challenging, owing to its slow and variable nature. This study develops deep learning algorithms that can measure GA growth rates with improved accuracy and robustness, by performing automated annotation of pre-existing versus newly expanding GA regions, based on simultaneous grading of fundus autofluorescence (FAF) image pairs. Design Retrospective analysis of data acquired in 2 independent prospective clinical trials (i.e., 830 images in AREDS2 [Age-Related Eye Disease Study 2] and 273 images in METformin for the MINimization of Geographic Atrophy Progression [METforMIN]). Participants One hundred seventy-four AREDS2 and 44 METforMIN participants. Methods A standard DeepLabV3+ (DL) segmentation model that automatically segments GA from a single FAF image (DeepLabV3+ STATIC [DLSTATIC]) was enhanced to input a longitudinally acquired, spatially aligned FAF image pair and to simultaneously segment regions corresponding to existing and expanding GA pixels (DeepLabV3+JOINT [DLJOINT]). This model was further modified to ensure longitudinal consistency of existing GA pixels (DLJOINT+SCL). Main outcome measures Image pixel overlap (using precision, recall, and Dice), GA area, and GA growth rates were measured with manual contours as the gold standard. The study also quantified the effect of longitudinal alignment of images to GA growth measurements. Results When compared to manual expert annotations, the DLJOINT+SCL model exhibited the highest performance, with precision (mean ± standard deviation) = 0.86 ± 0.13, recall = 0.92 ± 0.11, Dice = 0.89 ± 0.11, highest GA area correlation (R2 = 0.97), and highest growth rate correlation (R2 = 0.82). This shows the utility of simultaneously segmenting images when computing growth. Comparatively, the DLSTATIC model exhibited precision = 0.84 ± 0.13, recall = 0.93 ± 0.15, Dice = 0.87 ± 0.13, area correlation R2 = 0.94, and growth rate correlation R2 = 0.75. Spatial alignment via image registration was a key step that enabled the algorithm implementation; this yielded accuracy improvements when measuring GA growth by mapping regions to a common spatial coordinate system. Conclusions The simultaneous segmentation of longitudinal FAF images yielded improvements in accuracy and robustness by maintaining the longitudinal consistency of measurements. Such improvements are critical to the translation of automatic algorithms and minimizing measurement variability to effectively assess clinical trial outcomes in GA. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101110 · PubMed: 41847075

Spotted a mistake? Suggest a correction

More in Ophthalmology

ResearchPediatricAm J Ophthalmol · Nov 20, 2026 · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

Association of allergic conjunctivitis severity with meibomian gland abnormalities in children: a cross-sectional study

Randomized trialVisual abstractPediatricJAMA Ophthalmol · Nov 19, 2026 · Ophthalmology

Higher concentration atropine drops slowed myopia progression in children

Low-Concentration Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT2 Randomized Clinical Trial

ResearchAm J Ophthalmol · Nov 19, 2026 · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Smoke, Not Smoking, as a Possible Risk Factor Triggering Conversion in Leber's Hereditary Optic Neuropathy: A Retrospective Case Series

ResearchOphthalmology · Nov 18, 2026 · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Trends and Variation in Uveal Melanoma Management in the National Cancer Database, 2004-2023

ResearchAm J Ophthalmol · Nov 18, 2026 · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients

Developing Static Perimetry Thresholds to Assess Visual Field Loss Severity in Patients with Retinitis Pigmentosa