ResearchJournal of Allergy and Clinical Immunology: Global · May 8, 2026

Stability of proton pump inhibitors for use in hypersensitivity evaluation

Wanandy T, Handley SA, Patel RP, Anwar S, Le TA, Lau WY, et al
Allergy & ImmunologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Serious adverse drug reactions, including anaphylaxis and hypersensitivity reactions to proton pump inhibitors (PPIs), have been reported and are expected to rise as a result of their widespread use and over-the-counter availability. Relevant physicochemical stability information of PPIs for use in drug hypersensitivity evaluation is virtually unavailable. Appropriate shelf life determination of PPIs for skin testing will improve patient safety and streamline allergy testing procedures. Objective We studied the physicochemical stability of PPIs in plastic syringes. Methods PPIs' chemical stability was determined as a function of percentage of initial concentration remaining by a validated stability-indicating high-performance liquid chromatography method. Physical stability was monitored for the presence of precipitation, haziness, and color change by visible spectrophotometry and pH shift. Results At refrigerated temperature, esomeprazole and omeprazole at 40 mg/mL and 4 mg/mL were stable for up to 7 days, while pantoprazole was stable for 7 and 2 days at 40 mg/mL and 4 mg/mL, respectively. At room temperature, esomeprazole and omeprazole at 40 mg/mL and 4 mg/mL, and pantoprazole at 4 mg/mL were stable for up to 2 days. Rabeprazole 20 mg/mL and 2 mg/mL were unstable at room temperature. Conclusion Aseptically prepared 40 mg/mL and 4 mg/mL esomeprazole and omeprazole, and 40 mg/mL pantoprazole have a maximum shelf life of 7 days when stored at 2°C to 8°C. At room temperature, aseptically prepared 40 mg/mL and 4 mg/mL esomeprazole and omeprazole, and 4 mg/mL pantoprazole can be used within 2 days of preparation, while 20 mg/mL and 2 mg/mL rabeprazole should be prepared fresh and used within 24 hours.

DOI: 10.1016/j.jacig.2026.100732 · PubMed: 42256029

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Wanandy T, Handley SA, Patel RP, et al. Stability of proton pump inhibitors for use in hypersensitivity evaluation. J Allergy Clin Immunol Glob. 2026;5(4):100732. doi:10.1016/j.jacig.2026.100732

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Allergy & Immunology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

More in Allergy & Immunology

Randomized trial n = 43 · Eur Respir J · Nov 23, 2026 · Pulmonology, Allergy & Immunology

Inhaled itraconazole 40mg improved lung function and asthma control in adults with asthma and ABPA in a small phase 2 trial

Meta-analysis · J Allergy Clin Immunol Pract · Nov 22, 2026 · Allergy & Immunology

Adding TNF inhibitors to steroids showed earlier disease control in skin necrosis patients

Meta-analysis n = 25,134 · J Allergy Clin Immunol Pract · Nov 21, 2026 · Allergy & Immunology

Twice-daily and once-daily intranasal sprays showed no difference in allergic rhinitis outcomes

Research · JACI · Nov 20, 2026 · Allergy & Immunology

Non-immune features persisted in 98 percent of patients despite metabolic detoxification

Review · JACI · Nov 19, 2026 · Allergy & Immunology

Molecular information may improve diagnosis and treatment of inflammatory skin diseases