Studying Deep Inferior Epigastric Perforator Flap Perfusion Using the Isolated-perfused Human Abdominal Skin Flap
Abstract
Background
This study investigated dynamic deep inferior epigastric artery perforator flap perfusion in an ex vivo perfusion model using dynamic infrared thermography (DIRT) and indocyanine green fluorescence angiography (ICG-FA) and compared the results with static perfusion imaging using color dye injection technique and computed tomography angiography (CTA). Methods
Individual vessels were perfused with modified Krebs-Henseleit buffer (pH 7.4) in an isolated-perfused human abdominal skin flap perfusion model. Their perfusion patterns were sequentially evaluated with all 4 imaging techniques. Results
Perfusion patterns of 37 vessels in 19 hemi-deep inferior epigastric perforator (DIEP) flaps and 1 cross-midline DIEP flap were examined. DIRT and ICG-FA measurements of perforators displayed similar perfusion patterns and corresponded well with the colored skin area after dye injection. CTA showed equivalent 3-dimensional images of the selected perforator. Lateral and medial perforators had variable perfusion patterns but often drained into the superficial veins; and sometimes perfused both the medial and lateral flap zones. CTA revealed true anastomosis connecting 2 different perforators, whereas the other imaging modalities showed a large overlap on the skin. DIRT showed that the venous drainage can be rerouted between the ipsilateral and contralateral superficial inferior epigastric vein when 1 superficial inferior epigastric vein is obstructed in the cross-midline DIEP flap. Conclusions
DIRT and ICG-FA provided comparable and reproducible results that could easily be related to the skin perfusion area in the color dye experiments and CTA 3-dimensional reconstruction, supporting the use of DIRT and ICG-FA for evaluating and investigating DIEP flap perfusion in clinical and research settings.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training