Visual abstractsVisuals
Randomized trialCirculation · Apr 25, 2026

Subcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial

Knops RE, Marquie C, Nordbeck P, Tilz RR, Dijkshoorn LA, Quast ABE, et al
CardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background To improve survival of patients at risk of sudden cardiac death, subcutaneous implantable cardioverter defibrillators (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes on the basis of chest X-ray. The PRAETORIAN-DFT (Prospective Randomized Comparative Trial of Subcutaneous Implantable Cardioverter Defibrillator Implantation With and Without Defibrillation Testing) trial evaluated whether omission of DF testing guided by the PRAETORIAN score is noninferior for first-shock efficacy. Methods In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary end point was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for noninferiority with a 3% absolute risk margin. Secondary end points included mortality, potential DF testing-related complications, and S-ICD revisions. Results The included 965 patients (No-DF testing, n=483; DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (-0.6% [95% CI, -2.6 to 1.4], PConclusions PRAETORIAN score-guided omission of DF testing after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03495297.

Topics

Humans; Defibrillators, Implantable; Female; Male; Electric Countershock; Death, Sudden, Cardiac; Middle Aged; Aged; Prospective Studies; Treatment Outcome

DOI: 10.1161/CIRCULATIONAHA.126.080638 · PubMed: 42033346 · Registered: NCT03495297

Spotted a mistake? Suggest a correction

More in Cardiology

ResearchJACC Adv · Nov 23, 2026 · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

Meta-analysisJACC Adv · Nov 20, 2026 · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis

ResearchJACC Adv · Nov 20, 2026 · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms

ReviewLancet · Nov 19, 2026 · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research

ReviewJACC · Nov 19, 2026 · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk

Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology