Visual abstractsVisuals
ResearchResuscitation Plus · Jan 19, 2026

Survival with one versus three centimeters of active decompression during automated head-up CPR in a porcine cardiac arrest model

Pourzand P, Metzger A, Moore J, Salverda B, Hai H, Suresh M, et al
Emergency MedicineCardiologyCritical CareBasic science

Study type: Laboratory or animal research: results may not apply to people yet.

Read the full paper free at PubMed Central ↗

Abstract

Background Automated head-up (AHUP) CPR, combining controlled head/thorax elevation, active compression-decompression CPR, and an impedance threshold device, has shown improved survival with favorable neurological outcomes versus conventional (C) CPR. The optimal amount of active lift (AD) during AHUP-CPR to optimize survival remains unknown. This study focused primarily on 24-h survival with 1-cm of active lift (AL-1 cm) with a rectilinear waveform versus 3-cm of active lift (AL-3 cm) with a trapezoidal waveform during AHUP-CPR. Methods Anesthetized pigs (n = 24, ∼40 kg) were randomized to AL-1 cm or AL-3 cm after 10 min of ventricular fibrillation. CPR began with 2 min of C-CPR (21% AP depth, sinusoidal waveform, 100/min), followed by 18 min of AHUP-CPR using the assigned AL. Asynchronous ventilation (10 ml/kg, 10/min) was provided. Epinephrine and amiodarone were administered after 19 min of CPR with defibrillation 1 min later. Primary outcome: 24-h survival; Secondary outcomes: return of spontaneous circulation (ROSC), hemodynamics, epinephrine response, and neurological function (Neurological Deficit Score [NDS], 0 = normal, 320 = death). Statistical analyses included t-test, Kaplan-Meier, log-rank, and Mann-Whitney U tests. Results ROSC occurred in 6/12 pigs with AL-1 cm vs 12/12 with AL-3 cm (p = 0.03), and 24-h survival rates were 16.7% vs 41.7%, respectively (p = 0.04). Hemodynamics, ETCO2, epinephrine response, and changes in rSO2 values were significantly higher with AL-3 cm. NDS was 286 ± 79 (AL-1 cm) vs 213 ± 130 (AL-3 cm, p = 0.09). Conclusion 24-h survival rates were significantly higher with AL-3 cm vs AL-1 cm during AHUP-CPR. Together with improved hemodynamics observed with AL-3 cm, these outcomes underscore the critical importance of AL-3 cm to optimize AHUP-CPR.

DOI: 10.1016/j.resplu.2026.101231 · PubMed: 41658278

Cite this article

Pourzand P, Metzger A, Moore J, Salverda B, Hai H, Suresh M. Survival with one versus three centimeters of active decompression during automated head-up CPR in a porcine cardiac arrest model. Resusc Plus. 2026. doi:10.1016/j.resplu.2026.101231

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Emergency Medicine

J Med Internet Res · Nov 23, 2026 · Meta-analysis · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

BMJ Med · Nov 18, 2026 · Research · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Am J Emerg Med · Nov 13, 2026 · Research · Emergency Medicine, Hematology

ED red blood cell transfusion linked to longer hospital stays in severe anemia

J Med Internet Res · Nov 13, 2026 · Research · Digital Health & AI, Emergency Medicine

Physicians often intend to act on false information in AI-generated abstracts

Am J Emerg Med · Nov 12, 2026 · Research · Emergency Medicine, Neurology

Serum lactate levels differed across neurologic emergencies in emergency patients