Visual abstractsVisuals
ResearchJAMA Network Open · Mar 2, 2026

Suspended Lead Suits and Radiation Exposure in Interventional Echocardiographers

McNamara DA, Decker JM, McNamara MW, Kenaan MA, Cameron DM, VanOosterhout S, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Importance Percutaneous left atrial appendage occlusion (LAAO) is frequently performed with an interventional echocardiographer (IE) in close proximity to the patient and radiation source, increasing the risk for occupational radiation exposure. Yet optimal radiation shielding methods for IEs remain unknown. Objective To assess whether using a suspended lead suit reduces IE radiation dose compared with traditional lead apron shielding during LAAO procedures. Design, setting, and participants In this blinded cross-sectional study, IE radiation exposure data were prospectively collected during all LAAO procedures conducted for adults at a single quaternary care center from February 21 to August 22, 2023. Head-level dosimeters were worn by IEs who were using suspended lead suits during sequential LAAO procedures conducted at the center. Exposures Use of a suspended lead suit or traditional lead apron radiation protection device. Main outcomes and measures The primary outcome was measured personal dose equivalents at head level to IEs per case using real-time radiation dosimeters. Dosimeter-derived physician radiation doses and procedural radiation (dose area product) were compared with a control group of 30 sequential historical LAAO cases performed with IEs wearing traditional lead aprons from July 1, 2016, to January 31, 2018. Results Overall, 125 patients (mean [SD] age, 78 [8] years; 77 [61.6%] male) were included. Among 95 cases in which IEs used suspended lead suits, the median (IQR) radiation dose was 0.0 (0.0-0.3) μSv, which was significantly lower than 30 cases in which IEs wore traditional lead aprons (median [IQR], 10.6 [5.8-24.1] μSv; P Conclusions and relevance In this cross-sectional study, the use of suspended lead suits was associated with large reductions in head-level radiation doses to IEs compared with the use of traditional lead aprons during LAAO cases. These findings have important ramifications for the risk of occupational radiation exposure to IEs and potential shielding mechanisms during structural heart interventions.

Topics

Humans; Occupational Exposure; Cross-Sectional Studies; Radiation Exposure; Male; Female; Radiation Protection; Protective Clothing; Aged; Left Atrial Appendage Closure; Lead; Radiation Dosage

DOI: 10.1001/jamanetworkopen.2025.58134 · PubMed: 41811318

Spotted a mistake? Suggest a correction

More in Cardiology

JACC Adv · Nov 23, 2026 · Research · Cardiology

Building a Rural Cardiovascular Workforce Through Research Fellowship Immersion: Thad Waites Rural CVD Research Fellowship

JACC Adv · Nov 20, 2026 · Meta-analysis · Cardiology

Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations

JACC Adv · Nov 20, 2026 · Research · Cardiology

Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately

Lancet · Nov 19, 2026 · Review · Cardiology

Spontaneous coronary artery dissection affects younger women more often than expected

JACC · Nov 19, 2026 · Review · Cardiology

Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk