Synthetically trained convolutional neural networks for time-resolved aortic segmentation of four-dimensional flow magnetic resonance imaging

Wolkerstorfer G, Dirix P, Jahnke C, Paetsch I, Manka R, Buoso S, et al
Radiology & ImagingCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Supervised learning-based approaches are increasingly used for vessel segmentation in four-dimensional (4D) flow cardiovascular magnetic resonance (CMR). However, their widespread adoption is challenged by the need for diverse, reliably annotated datasets, sensitivity to acquisition and reconstruction settings, and the lack of fully defined ground truth. Methods In this study, we investigated the use of realistic, fluid mechanics-informed synthetic 4D flow CMR data to train convolutional neural networks for time-resolved aortic segmentation. The availability of fully defined ground-truth vessel geometries in synthetic data enabled quantitative evaluation before evaluation on in vivo data acquired across three scanners with varying field strengths and protocols. Four training strategies were evaluated: one using in vivo data only (R-28) and three based on increasing amounts and diversity of synthetic data (S-28, S-multi, and S-full). Performance was assessed using voxel- and surface-based metrics, including Dice similarity coefficient (DSC), Hausdorff distance (HD), and Bland-Altman analysis. Results The S-full model achieved the best performance on the in vivo test dataset, with a DSC of 0.956 ± 0.017 and a HD of (1.7 ± 1.5) mm, relative to reference annotations. Bland-Altman analysis of cross-sectional areas showed small biases and narrow limits of agreement, with 1.1% [-10.9, 13.1]% for the ascending aorta and -1.0% [-13.1, 11.1]% for the descending aorta. For the in vivo trained model (R-28) evaluated on synthetic data, relative cross-sectional area measurements yielded biases of 3.1% [-10.9, 17.0]% in the ascending aorta and 4.0% [-8.2, 16.2]% in the descending aorta, relative to synthetic ground truth. Conclusion This work demonstrates that purely synthetic 4D flow CMR can be used to train neural networks for time-resolved aortic segmentation of in vivo 4D flow CMR data, enabling fully automatic inference and quantitative evaluation against fully defined ground truth.

Topics

Humans; Aorta; Blood Flow Velocity; Convolutional Neural Networks; Hemodynamics; Image Interpretation, Computer-Assisted; Magnetic Resonance Angiography; Predictive Value of Tests; Regional Blood Flow; Reproducibility of Results; Supervised Machine Learning; Time Factors

DOI: 10.1016/j.jocmr.2026.102735 · PubMed: 42025769

Cite this article

Wolkerstorfer G, Dirix P, Jahnke C, Paetsch I, Manka R, Buoso S. Synthetically trained convolutional neural networks for time-resolved aortic segmentation of four-dimensional flow magnetic resonance imaging. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102735

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Cardiovasc Magn Reson · Apr 20, 2026 · Research · Radiology & Imaging, Cardiology

Aortic displacement and hemodynamics are abnormal in patients with Marfan syndrome: A combined four-dimensional balanced steady-state free precession and four-dimensional flow cardiac magnetic resonance study

J Cardiovasc Magn Reson · Jan 29, 2026 · Research · Radiology & Imaging, Cardiology

Feasibility and reproducibility of semi-automated magnetic resonance angiography measurements of the thoracic aorta using commercial software

J Cardiovasc Magn Reson · Apr 18, 2026 · Research · Radiology & Imaging, Cardiology

A radiomics-based approach with automated segmentation for identifying symptomatic basilar artery plaques in acute stroke

J Cardiovasc Magn Reson · Apr 17, 2026 · Research · Radiology & Imaging, Cardiology

Assessing changes in aortic motion and hemodynamics after valve-sparing aortic root surgery in Marfan syndrome using four-dimensional balanced steady-state free precession and four-dimensional flow cardiovascular magnetic resonance

J Am Heart Assoc · Feb 11, 2026 · Research · Cardiology, Neurology

Associations Between Hemodynamics, Shape and Atherosclerosis in M1 of Middle Cerebral Artery: Insights From 4-Dimensional Flow Magnetic Resonance Imaging in Patients With Ischemic Stroke