Systematic Review and Network Meta-analysis of Neurostimulation for Painful Diabetic Neuropathy
Key result: High-frequency and low-frequency spinal cord stimulation both provide more pain relief than medical management alone
Key points
- Researchers analyzed randomized controlled trials comparing different spinal cord stimulation waveforms for painful diabetic neuropathy.
- High-frequency spinal cord stimulation showed a mean difference of -5.20 in pain intensity compared to conventional medical management alone.
- Low-frequency spinal cord stimulation was associated with a mean difference of -3.13 in pain intensity compared to conventional medical management alone.
Why it matters: Direct or indirect comparisons between different spinal cord stimulation waveforms for managing painful diabetic neuropathy had not been performed.
Limitation the authors note: There was a limited number of randomized controlled trials and no head-to-head randomized controlled trials conducted.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Duarte RV, Nevitt S, Copley S, et al. Systematic Review and Network Meta-analysis of Neurostimulation for Painful Diabetic Neuropathy. Diabetes Care. 2022;45(10):2466-2475. doi:10.2337/dc22-0932