Visual abstractsVisuals
ResearchERJ Open Research · Dec 15, 2025

The safety, physiological response and repeatability of the incremental shuttle walk test in survivors of COVID-19

Baldwin MM, Daynes E, Karsanji U, McAuley HJC, Bishop NC, Bolton CE, et al
PulmonologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background The incremental shuttle walk test (ISWT) may be a valuable tool for measuring exercise tolerance in patients after a hospital admission with COVID-19. However, the safety, physiological response and repeatability of the ISWT are unknown in this cohort. The present study aimed to explore the properties of this test using the Post-Hospital COVID-19 (PHOSP-COVID) study. Methods Participants performed two ISWTs, with a 30-min rest between tests, at 5 and 12 months post-hospital discharge for COVID-19. Heart rate and fingertip peripheral oxygen saturation were recorded pre- and post-test. Reasons for test termination were noted. Results 1593 individuals (median (interquartile range) age 58 (50-66) years and body mass index 31.2 (27.6-35.8) kg·m- 2; 967 (60.7%) males) performed an ISWT; two tests were performed by 1034 and 390 participants at the 5- and 12-month visit, respectively. At 5 months post-discharge, six patients (0.4%) had an adverse event and the most common reason contributing to test termination was breathlessness (826 (54.2%) participants). 336/1470 (22.9%) participants experienced exertional desaturation. Distance walked was greater in the second ISWT compared to the first ISWT at 5 and 12 months post-discharge (mean±sd difference: 5 months: 19±94 m; 12 months: 11±80 m; pConclusions The ISWT appeared to be safe in this large cohort, supporting use of this field walking test for this population in clinical and research settings. A familiarisation test is recommended, with further study needed to determine the number of familiarisation tests required to achieve acceptable within-day repeatability.

DOI: 10.1183/23120541.00089-2025 · PubMed: 41403426

Cite this article

Baldwin MM, Daynes E, Karsanji U, McAuley HJC, Bishop NC, Bolton CE. The safety, physiological response and repeatability of the incremental shuttle walk test in survivors of COVID-19. ERJ Open Res. 2025. doi:10.1183/23120541.00089-2025

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Pulmonology

Eur Respir J · Nov 23, 2026 · Review · Pulmonology

BMP-9 and BMP-10 regulate pulmonary vascular resilience through complex pathways

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Needle aspiration reduced hospital stay by nearly five days for pneumothorax patients

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Inhaled itraconazole improved lung function and asthma control at 40mg dose

Chest · Nov 21, 2026 · Research · Pulmonology

Association between exertional dyspnea and insomnia in a population-based cohort

Chest · Nov 21, 2026 · Research · Pulmonology

Combination therapy reduces obstructive sleep apnea severity by roughly half