Negative pressure wound therapy and flap reconstruction were associated with higher ventricular assist device salvage rates
Threatened Ventricular Assist Devices: Meta-analysis of Negative Pressure Therapy and Flap Reconstruction Outcomes
Why it matters: The efficacy of using flaps and negative pressure wound therapy to save hardware in infected ventricular assist device wounds remains understudied.
Key points
- Researchers performed a meta-analysis of 29 studies involving 74 subjects with infected ventricular assist device wounds.
- Negative pressure wound therapy was associated with 77.4% salvage compared to 46.5% without it, and flap reconstruction was associated with 68.6% salvage compared to 39.1% without it.
- The odds of device salvage were three times higher with flap reconstruction and four times higher with negative pressure wound therapy.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Cite this article
Clark RC, Swanson MA, Cai Y, Sarode AL, Lineberry KD, Kumar AR. Threatened Ventricular Assist Devices: Meta-analysis of Negative Pressure Therapy and Flap Reconstruction Outcomes. Plast Reconstr Surg Glob Open. 2022. doi:10.1097/GOX.0000000000004627
Spotted a mistake? Suggest a correction