Three-dimensional transvaginal ultrasound vs magnetic resonance imaging for preoperative staging of deep myometrial and cervical invasion in patients with endometrial cancer: systematic review and meta-analysis
Key result: Three-dimensional ultrasound shows similar accuracy to magnetic resonance imaging for staging endometrial cancer
Systematic review and meta-analysisNo clear difference
Is three-dimensional transvaginal ultrasound as accurate as magnetic resonance imaging for endometrial cancer staging?
Who
450
Patients with endometrial cancer
Compared
77%Three-dimensional transvaginal ultrasound for deep myometrial infiltration (95% CI, 66-85%)
80%Magnetic resonance imaging for deep myometrial infiltration (95% CI, 73-86%)
Main outcome
Diagnostic accuracy for deep myometrial infiltration and cervical invasion
Result: P = 0.80 for similar diagnostic accuracy of deep myometrial infiltration
Bottom line: Three-dimensional transvaginal ultrasound shows comparable diagnostic accuracy to magnetic resonance imaging for preoperative staging in endometrial cancer.
Ultrasound Obstet Gynecol · 2022-06-04 · Save PNG
Key points
- Researchers analyzed five studies involving 450 patients to compare three-dimensional transvaginal ultrasound and magnetic resonance imaging for detecting cancer spread.
- For deep myometrial infiltration, three-dimensional transvaginal ultrasound had a 77% sensitivity compared to 80% for magnetic resonance imaging.
- The diagnostic accuracy for identifying deep myometrial infiltration was found to be similar between the two imaging methods.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Spagnol G, Noventa M, Bonaldo G, et al. Three-dimensional transvaginal ultrasound vs magnetic resonance imaging for preoperative staging of deep myometrial and cervical invasion in patients with endometrial cancer: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2022;60(5):604-611. doi:10.1002/uog.24967
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/three-dimensional-transvaginal-ultrasound-vs-magnetic-resonance-t5p4jv/ (AI-assisted from the abstract; check the paper before relying on it).