Visual abstractsVisuals
ResearchThorax · May 14, 2026

Tool in lesion verification of shape-sensing robotic-assisted bronchoscopy with cone beam CT in sampling peripheral pulmonary nodules

Chan LT, Lau KKW, Orton CM, Temov K, Tana A, Baboolal I, et al
PulmonologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Introduction Our aim was to evaluate the diagnostic and safety performance of shape-sensing robotic-assisted bronchoscopy (ssRAB) with cone beam CT (CBCT) for the biopsy of pulmonary nodules. Additional analysis was performed to assess outcomes for small nodules and those close to the fissure, pleura or mediastinum. Methods This single arm, multicentre prospective study enrolled 200 subjects with suspicious pulmonary nodules. Each subject underwent a ssRAB procedure with CBCT and was subsequently followed up. The primary outcome was tool-in-lesion (TIL) confirmed with CBCT. Further endpoints included diagnostic outcomes and rate of adverse events. Results Of 200 subjects recruited, 198 subjects had a successful biopsy (whereby lesion was reached and sample was taken) and 97% completed the required follow-up. The median size of the nodules was 13 mm; 26.8% (60/224) have a positive bronchus sign and 181 (80.8%) were located in the outer two-thirds of the lung. TIL was obtained in 99.0% (198/200). The strict diagnostic yield was 85% (170/200) with diagnostic accuracy of 92.0% (184/200) and sensitivity for malignancy of 95.5% (147/154). Diagnostic accuracy for nodules under 20 mm size, within 5 mm from a critical structure (eg, heart, aorta or main pulmonary artery) or from the pleura was 88.2% (172/195), 100% (11/11) and 93.3% (56/60), respectively. There were four (2%) serious procedure-related adverse events, with one patient (0.5%) suffering a pneumothorax. Conclusion ssRAB with CBCT can effectively reach and biopsy small pulmonary nodules, including perifissural, peripleural and paramediastinal lesions with a strong safety profile. Trial registration number NCT05867953.

Abstract reproduced under the article’s CC BY NC licence.

Topics

Humans; Male; Bronchoscopy; Female; Prospective Studies; Cone-Beam Computed Tomography; Middle Aged; Aged; Multiple Pulmonary Nodules; Lung Neoplasms; Solitary Pulmonary Nodule; Adult

DOI: 10.1136/thorax-2025-223631 · PubMed: 41391887 · Registered: NCT05867953

Cite this article

Chan LT, Lau KKW, Orton CM, Temov K, Tana A, Baboolal I. Tool in lesion verification of shape-sensing robotic-assisted bronchoscopy with cone beam CT in sampling peripheral pulmonary nodules. Thorax. 2026. doi:10.1136/thorax-2025-223631

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Clin Cancer Res · May 11, 2026 · Research · Oncology

A Noninvasive Circulating Tumor DNA Methylation Classifier to Identify Benign Pulmonary Nodules

Chest · Mar 16, 2026 · Research · Pulmonology

Association of New and Growing Nodules With Malignancy in Follow-Up Screening for Lung Cancer: A Cohort Study

Ann Surg · Jun 10, 2026 · Research · Surgery

Combining Commercial Cancer Protein Biomarkers and Benign Fungal Antibodies Improves Diagnostic Accuracy in Pulmonary Nodules

Chest · Mar 25, 2026 · Research · Pulmonology

Cone Beam CT Imaging-Guided Bronchoscopy vs CT Imaging-Guided Transthoracic Needle Biopsy for Peripheral Pulmonary Lesion Diagnosis

Radiology · Jan 27, 2026 · Research · Radiology & Imaging

Pulmonary Nodule Prevalence at CT in Middle-Aged Participants from the Swedish CArdioPulmonary bioImage Study (SCAPIS)